Perryman
Bush River Neck Rd, Harford County, MD 21130Plant Summary Information
Perryman is ranked #13 out of 202 power plants in Maryland in terms of total annual net electricity generation.
Perryman is comprised of 5 generators and generated 75.3 GWh during the 3-month period between September 2025 to December 2025.
| Plant Name | Perryman |
|---|---|
| Utility Name | Constellation Power Source Generation, LLC |
| Location | Harford County, MD |
| Initial Operation Date | January 1972 |
| Last Update | Dec 2025 |
| Annual Generation | 250.8 GWh |
| Annual Consumption | 2.9 M MMBtu |
| Ranked #2,229 out of 12,613 Power Plants Nationwide | |
| Ranked #725 out of 2,246 Natural Gas Power Plants Nationwide | |
| Ranked #13 out of 202 Maryland Power Plants | |
| Ranked #7 out of 19 Maryland Natural Gas Power Plants | |
| Fuel Types | Natural Gas : 84.1% Distillate Fuel Oil : 15.9% |
| Previous Operator |
Constellation Power Source Gen (2013 to 2021) Constellation Power Source Generation, LLC (2022 to 2024) |
Map of Perryman
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Perryman.
Monthly Net Generation for Perryman
Monthly Plant Fuel Consumption for Perryman
Perryman Details
| Summary Information | |
|---|---|
| Plant Name | Perryman (1556) |
| Plant Address | Bush River Neck Rd, Harford County, MD 21130 |
| Utility | Constellation Power Source Generation, LLC (4161) |
| Latitude, Longitude | 39.44284, -76.22176 |
| Generation Dates on File | Jan 2001 to Dec 2025 |
| Initial Operation Date | January 1972 |
| Annual Generation | 250.8 GWh |
| Fuel Types | Natural Gas : 84.1% Distillate Fuel Oil : 15.9% |
| Federal Energy Regulatory Commission (FERC) Information | |
| FERC Cogeneration Status | No |
| FERC Small Power Producer Status | No |
| FERC Exempt Wholesale Generator Status | Yes |
| FERC Exempt Wholesale Generator Docket Number | 01-91-000 |
| Regulatory Information | |
|---|---|
| Regulatory Status | Non-Regulated |
| NERC Region | RFC |
| Balancing Authority | PJM Interconnection, LLC (PJM) |
| NAICS Code | Utilities (22) |
| Sector | IPP Non-CHP (2) |
| Water Source | |
| Ash Impoundment | No |
| Transmission / Distribution Owner | Baltimore Gas & Electric Co (1167) MD |
| Grid Voltage | 115.00 kV |
| Energy Storage | No |
| Natural Gas Information | |
| Local Distribution Company (LDC) | BGE |
| Natural Gas Storage | No |
Generator GT1 Details Operating January 1972
| Technology | Petroleum Liquids |
|---|---|
| Prime Mover | Combustion Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | PERRYMAN13 KVCT 1 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | PERRYMAN13 KVCT 1 |
| Nameplate Capacity | 53.1 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 52 MW |
| Winter Capacity | 64.8 MW |
| Minimum Load | 5 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | January 1972 |
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Other Planned Modifications | No |
| Multiple Fuels | No |
Generator GT3 Details Operating April 1972
| Technology | Petroleum Liquids |
|---|---|
| Prime Mover | Combustion Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | PERRYMAN13 KVCT 3 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | PERRYMAN13 KVCT 3 |
| Nameplate Capacity | 53.1 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 51 MW |
| Winter Capacity | 63.6 MW |
| Minimum Load | 5 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | April 1972 |
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Other Planned Modifications | No |
| Multiple Fuels | No |
Generator GT4 Details Operating April 1972
| Technology | Petroleum Liquids |
|---|---|
| Prime Mover | Combustion Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | PERRYMAN13 KVCT 4 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | PERRYMAN13 KVCT 4 |
| Nameplate Capacity | 53.1 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 52 MW |
| Winter Capacity | 64.8 MW |
| Minimum Load | 5 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | April 1972 |
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Other Planned Modifications | No |
| Multiple Fuels | No |
Generator GT5 Details Operating June 1995
| Technology | Natural Gas Fired Combustion Turbine |
|---|---|
| Prime Mover | Combustion Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | PERRYMAN33 KVCT 51 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | PERRYMAN33 KVCT 51 |
| Nameplate Capacity | 192 MW |
| Nameplate Power Factor | 0.9 |
| Summer Capacity | 139 MW |
| Winter Capacity | 172.9 MW |
| Minimum Load | 110 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
| First Operation Date | June 1995 |
|---|---|
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Other Planned Modifications | No |
| Multiple Fuels | Yes |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Switch When Operating | No |
|---|---|
| Net Summer Capacity With Natural Gas | 139 MW |
| Net Winter Capacity With Natural Gas | 145 MW |
| Net Summer Capacity With Oil | 139 MW |
| Net Winter Capacity With Oil | 149 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 1H |
| Factors That Limit Switching | No |
Generator GT6 Details Operating June 2015
| Technology | Natural Gas Fired Combustion Turbine |
|---|---|
| Prime Mover | Combustion Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | PERRYMN613.8 KV PERYMAN6 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | PERRYMN613.8 KV PERYMAN6 |
| Nameplate Capacity | 141 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 109.8 MW |
| Winter Capacity | 128.7 MW |
| Minimum Load | 60 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
| First Operation Date | June 2015 |
|---|---|
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Other Planned Modifications | No |
| Multiple Fuels | Yes |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Switch When Operating | Yes |
|---|---|
| Net Summer Capacity With Natural Gas | 109 MW |
| Net Winter Capacity With Natural Gas | 120 MW |
| Net Summer Capacity With Oil | 109 MW |
| Net Winter Capacity With Oil | 109 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 1H |
| Factors That Limit Switching | Yes |
| Air Permit Limits | Yes |
Perryman Plant Owners
| Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
|---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
| Rank | Plant Name | Plant Location | Annual Generation |
|---|---|---|---|
| #715 | Kimberly Clark-Unit 1,2,3 | New Milford, CT | 219.0 GWh |
| #716 | Sycamore Cogeneration | Bakersfield, CA | 218.9 GWh |
| #717 | Elm Road Generating Station | Oak Creek, WI | 7.4 TWh |
| #718 | Carlsbad Energy Center | Carlsbad, CA | 216.2 GWh |
| #719 | Calvert City | Calvert City, KY | 215.8 GWh |
| #720 | University of Michigan | Ann Arbor, MI | 213.0 GWh |
| #721 | Central Utility Plant Cincinnati | Cincinnati, OH | 214.5 GWh |
| #722 | Dahlberg | Nicholson, GA | 229.4 GWh |
| #723 | Charles D. Lamb Energy Center | Ponca City, OK | 211.8 GWh |
| #724 | UCLA So Campus Cogen Project | Los Angeles, CA | 211.2 GWh |
| #726 | Atlantic Alumina, Gramercy Operations | Gramercy, LA | 208.1 GWh |
| #727 | Limon Generating Station | Limon, CO | 216.3 GWh |
| #728 | Roquette America | Keokuk, IA | 207.4 GWh |
| #729 | University of California San Diego Hybri | La Jolla, CA | 206.8 GWh |
| #730 | University of Illinois Abbott Power Plt | Champaign, IL | 211.1 GWh |
| #731 | Chino Mines | Hurley, NM | 205.4 GWh |
| #732 | Exelon West Medway II LLC | Medway, MA | 210.9 GWh |
| #733 | Mass Inst Tech Cntrl Utilities/Cogen Plt | Cambridge, MA | 204.8 GWh |
| #734 | Cass County | Plattsmouth, NE | 202.4 GWh |
| #735 | Smarr Energy Center | Forsyth, GA | 202.0 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Perryman.
| Plant Name | Plant Location | Annual Generation | Distance |
|---|---|---|---|
| APG Combined Heat and Power Plant | Edgewood, MD | 53.0 GWh | 5.2 mi |
| APG New Chesapeake | Aberdeen, MD | 4.1 GWh | 5.3 mi |
| APG Old Bayside | Aberdeen, MD | 3.0 GWh | 5.6 mi |
| Archdiocese of Baltimore J | Perryman, MD | 3.3 GWh | 0.3 mi |
| Archdiocese of Baltimore L | Perryman, MD | 3.3 GWh | 0.3 mi |
| Baltimore City B | Perryman, MD | 2.0 GWh | 0.5 mi |
| Baltimore City D | Perryman, MD | 3.1 GWh | 0.5 mi |
| Baltimore City F | Perryman, MD | 3.1 GWh | 0.5 mi |
| Baltimore City G | Perryman, MD | 2.9 GWh | 0.5 mi |
| BTC2 Solar (CSG) | Kingsville, MD | 3.8 GWh | 9.5 mi |
| City of Havre De Grace C | Perryman, MD | 3.3 GWh | 0.5 mi |
| Eastern Landfill Gas LLC | White Marsh, MD | 25.3 GWh | 9.8 mi |
| Fairview Farms | Bel Air, MD | 20.6 GWh | 5.8 mi |
| Havre de Grace II - E at Perryman | Perryman, MD | 1.9 GWh | 0.5 mi |
| Macy's MD Joppa Solar Project | Joppa, MD | 2.3 GWh | 5.3 mi |
| McCormick & Co. Inc. at Belcamp | Belcamp, MD | 2.2 GWh | 2.8 mi |
| Pfeffers | Kingsville, MD | 1.9 GWh | 9.2 mi |
| Sod Run WTP A | Perryman, MD | 3.3 GWh | 0.5 mi |
| The Clorox Company | Aberdeen, MD | 2.4 GWh | 2.3 mi |
| White Marsh Solar | White Marsh, MD | 2.6 GWh | 9.8 mi |