Lincoln Combustion

6769 Old Plank Road, Stanley, NC 28164

Plant Summary Information

Lincoln Combustion is ranked #19 out of 873 power plants in North Carolina in terms of total annual net electricity generation.

Lincoln Combustion is comprised of 17 generators and generated 459.7 GWh during the 3-month period between June 2025 to September 2025.

Plant NameLincoln Combustion
Utility NameDuke Energy Carolinas, LLC
LocationLincoln County, NC
Initial Operation DateMay 1995
Last Update Sep 2025
Annual Generation 797.4 GWh
Annual Consumption 8.6 M MMBtu
Ranked #892 out of 12,539 Power Plants Nationwide
Ranked #479 out of 2,243 Natural Gas Power Plants Nationwide
Ranked #19 out of 873 North Carolina Power Plants
Ranked #13 out of 27 North Carolina Natural Gas Power Plants
Fuel Types Natural Gas : 99.9%

Map of Lincoln Combustion

Full Screen Map

Register Now for Comprehensive Access

Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Lincoln Combustion.

Create Your Account Today

Monthly Net Generation for Lincoln Combustion

Lincoln Combustion Details

Summary Information
Plant NameLincoln Combustion (7277)
Plant Address6769 Old Plank Road, Stanley, NC 28164
UtilityDuke Energy Carolinas, LLC (5416)
Latitude, Longitude35.4317, -81.0347
Generation Dates on FileJan 2001 to Sep 2025
Initial Operation DateMay 1995
Annual Generation 797.4 GWh
Fuel Types Natural Gas : 99.9%
 
Federal Energy Regulatory Commission (FERC) Information
FERC Cogeneration StatusNo
FERC Small Power Producer StatusNo
FERC Exempt Wholesale Generator StatusNo
Regulatory Information
Regulatory StatusRegulated
NERC RegionSERC
Balancing AuthorityDuke Energy Carolinas (DUK)
NAICS CodeUtilities (22)
Sector Electric Utility (1)
Water SourceKillian Creek
Ash Impoundment No
Transmission / Distribution OwnerDuke Energy Carolinas, LLC (5416) NC
Grid Voltage 230.00 kV
Energy StorageNo
 
Natural Gas Information
Local Distribution Company (LDC)PIEDMONT NATURAL GAS
Natural Gas StorageNo
Liquefied Natural Gas StorageNo

Generator 10 Details Operating November 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity73 MW
Winter Capacity96 MW
Minimum Load73 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateNovember 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas75 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil75 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 9 Details Operating November 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity71 MW
Winter Capacity94 MW
Minimum Load71 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateNovember 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingNo
Net Summer Capacity With Natural Gas75 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil75 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 11 Details Operating December 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity73 MW
Winter Capacity95 MW
Minimum Load73 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateDecember 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil74 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 12 Details Operating December 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity73 MW
Winter Capacity94 MW
Minimum Load73 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateDecember 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas75 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil75 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 1 Details Operating May 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity73 MW
Winter Capacity94 MW
Minimum Load73 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas76 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil76 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 2 Details Operating May 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity74 MW
Winter Capacity96 MW
Minimum Load74 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas76 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil76 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 3 Details Operating June 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity73 MW
Winter Capacity95 MW
Minimum Load73 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas75 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil75 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 4 Details Operating June 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity73 MW
Winter Capacity94 MW
Minimum Load73 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas75 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil75 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 5 Details Operating July 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity72 MW
Winter Capacity93 MW
Minimum Load72 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJuly 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil74 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 6 Details Operating July 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity72 MW
Winter Capacity93 MW
Minimum Load72 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJuly 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas73 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil73 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 7 Details Operating September 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity72 MW
Winter Capacity95 MW
Minimum Load72 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateSeptember 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas76 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil76 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 8 Details Operating September 1995

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity72 MW
Winter Capacity94 MW
Minimum Load72 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateSeptember 1995
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas75 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil75 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 13 Details Operating February 1996

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity72 MW
Winter Capacity93 MW
Minimum Load72 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateFebruary 1996
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil74 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 14 Details Operating February 1996

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity72 MW
Winter Capacity94 MW
Minimum Load72 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateFebruary 1996
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil74 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 15 Details Operating March 1996

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity73 MW
Winter Capacity94 MW
Minimum Load73 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMarch 1996
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas73 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil73 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 16 Details Operating March 1996

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity109.6 MW
Nameplate Power Factor0.9
Summer Capacity73 MW
Winter Capacity93 MW
Minimum Load73 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMarch 1996
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas73 MW
Net Winter Capacity With Natural Gas93 MW
Net Summer Capacity With Oil73 MW
Net Winter Capacity With Oil93 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Generator 17 Details Operating December 2024

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity536.4 MW
Nameplate Power Factor0.85
Summer Capacity365 MW
Winter Capacity402 MW
Minimum Load130 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateDecember 2024
Sector NameElectric Utility (1)
Energy SourceNatural Gas / Distillate Fuel Oil
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas365 MW
Net Winter Capacity With Natural Gas402 MW
Net Summer Capacity With Oil365 MW
Net Winter Capacity With Oil402 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Storage LimitsYes
Air Permit LimitsYes

Lincoln Combustion Plant Owners

Owner NameAddressGeneratorOwnership
We couldn't locate any owners for this plant

Power Plants with Similar Net Generation

Power plants with a similar annual net generation from Natural Gas.

RankPlant NamePlant LocationAnnual Generation
#469Power IslandAlvin, TX833.4 GWh
#470Pine Bluff Energy CenterPine Bluff, AR827.1 GWh
#471Washington County Cogeneration FacilityMcIntosh, AL825.9 GWh
#472Broad River Energy CenterGaffney, SC817.1 GWh
#473Little GypsyLa Place, LA815.1 GWh
#474Plant XEarth, TX815.7 GWh
#475Brame Energy CenterLena, LA2.5 TWh
#476John R KellyGainesville, FL807.2 GWh
#477R W MillerPalo Pinto, TX799.8 GWh
#478JM Shafer Generating StationFt. Lupton, CO798.1 GWh
#480Las Vegas Generating StationNorth Las Vegas, NV792.2 GWh
#481Invenergy Nelson Expansion LLCRock Falls, IL780.8 GWh
#482SouthwesternAnadarko, OK779.4 GWh
#483LadysmithWoodford, VA901.2 GWh
#484DeanEast China, MI770.1 GWh
#485Greenland Energy CenterJacksonville, FL770.9 GWh
#486Freeport Energy CenterFreeport, TX766.1 GWh
#487T H WhartonHouston, TX763.4 GWh
#488Martinez RefiningMartinez, CA790.0 GWh
#489NaughtonKemmerer, WY2.3 TWh

Nearby Power Plants

Below are closest 20 power plants surrounding Lincoln Combustion.

Plant NamePlant LocationAnnual GenerationDistance
Auten Road Farm, LLCGastonia, NC8.6 GWh10.5 mi
Cowans FordStanley, NC182.0 GWh4.3 mi
DE Solar 10240 Old Dowd RdCharlotte, NC1.9 GWh13 mi
DE Solar 1725 Drywall DrMt. Holly, NC902.0 MWh7.6 mi
Freemont Solar Center LLCStanley, NC7.2 GWh2.1 mi
Gaston County Renewable Energy CenterDallas, NC19.8 GWh8.4 mi
Gaston Memorial HospitalGastonia, NC22.0 MWh12.3 mi
Gaston Solar Power PlantCherryville Township, NC42.8 GWh9.4 mi
Gastonia Prime Power ParkDallas, NC162.0 MWh13.3 mi
Haynes FarmLincolnton, NC7.2 GWh13 mi
High Shoals Hydro (NC)High Shoals, NC3.7 GWh9.7 mi
High Shoals PV1High Shoals, NC28.9 GWh10.7 mi
Lincolnton High SchoolLincolnton, NC87.0 MWh13.2 mi
Long Creek Waste Water PlantDallas, NC402.0 MWh10.2 mi
Maiden Creek Solar Power PlantMaiden, NC116.7 GWh13.4 mi
Mariposa Solar Center LLCStanley, NC8.9 GWh5 mi
Marshall (NC)Terrell, NC7.8 TWh12.1 mi
McGuireHuntersville, NC19.9 TWh4.8 mi
Mountain IslandMount Holly, NC131.1 GWh7.3 mi
Reventure ParkCharlotte, NC23.6 GWh9.7 mi