Port Washington Generating Station
146 South Wisconsin Street, Port Washington, WI 53074Plant Summary Information
Port Washington Generating Station is ranked #39 out of 2,243 natural gas power plants nationwide in terms of total annual net electricity generation.
Port Washington Generating Station is comprised of 6 generators and generated 2.2 TWh during the 3-month period between June 2025 to September 2025.
| Plant Name | Port Washington Generating Station |
|---|---|
| Utility Name | Wisconsin Electric Power Co |
| Location | Ozaukee County, WI |
| Initial Operation Date | July 2005 |
| Last Update | Sep 2025 |
| Annual Generation | 7.2 TWh |
| Annual Consumption | 54.5 M MMBtu |
| Ranked #124 out of 12,539 Power Plants Nationwide | |
| Ranked #39 out of 2,243 Natural Gas Power Plants Nationwide | |
| Ranked #3 out of 239 Wisconsin Power Plants | |
| Ranked #1 out of 52 Wisconsin Natural Gas Power Plants | |
| Fuel Types | Natural Gas |
Map of Port Washington Generating Station
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Port Washington Generating Station.
Monthly Net Generation for Port Washington Generating Station
Port Washington Generating Station Details
| Summary Information | |
|---|---|
| Plant Name | Port Washington Generating Station (4040) |
| Plant Address | 146 South Wisconsin Street, Port Washington, WI 53074 |
| Utility | Wisconsin Electric Power Co (20847) |
| Latitude, Longitude | 43.3842, -87.8689 |
| Generation Dates on File | Jan 2001 to Sep 2025 |
| Initial Operation Date | July 2005 |
| Annual Generation | 7.2 TWh |
| Fuel Types | Natural Gas |
| Federal Energy Regulatory Commission (FERC) Information | |
| FERC Cogeneration Status | No |
| FERC Small Power Producer Status | No |
| FERC Exempt Wholesale Generator Status | No |
| Regulatory Information | |
|---|---|
| Regulatory Status | Regulated |
| NERC Region | RFC |
| Balancing Authority | Midcontinent Independent Transmission System Operator, Inc.. (MISO) |
| NAICS Code | Utilities (22) |
| Sector | Electric Utility (1) |
| Water Source | Lake Michigan |
| Ash Impoundment | No |
| Transmission / Distribution Owner | American Transmission Co (659) WI |
| Grid Voltage | 138.00 kV |
| Energy Storage | No |
| Natural Gas Information | |
| Pipeline Name | ANR PIPELINE COMPANY |
| Natural Gas Storage | No |
Generator 2CT1 Details Operating July 2005
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Combustion Turbine Part |
| Unit Code | PWG2 |
| Ownership | Wholly Owned by Other Entity |
| Can Bypass Heat Recovery Steam Generator | No |
| RTO ISO LMP Node Designation | WEC.PORTWCT1 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | WEC.PORTWCT1 |
| Nameplate Capacity | 173.1 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 174.8 MW |
| Winter Capacity | 204.2 MW |
| Minimum Load | 101 MW |
| Uprate/Derate Completed | No |
|---|---|
| Status | Operating |
| First Operation Date | July 2005 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 12H |
| Multiple Fuels | No |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | No |
Generator 2CT2 Details Operating July 2005
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Combustion Turbine Part |
| Unit Code | PWG2 |
| Ownership | Wholly Owned by Other Entity |
| Can Bypass Heat Recovery Steam Generator | No |
| RTO ISO LMP Node Designation | WEC.PORTWCT2 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | WEC.PORTWCT2 |
| Nameplate Capacity | 173.1 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 174.9 MW |
| Winter Capacity | 204.5 MW |
| Minimum Load | 101 MW |
| Uprate/Derate Completed | No |
|---|---|
| Status | Operating |
| First Operation Date | July 2005 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 12H |
| Multiple Fuels | No |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | No |
Generator ST2 Details Operating July 2005
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Steam Part |
| Unit Code | PWG2 |
| Ownership | Wholly Owned by Other Entity |
| Duct Burners | Yes |
| RTO ISO LMP Node Designation | WEC.PORTWST1 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | WEC.PORTWST1 |
| Nameplate Capacity | 268.6 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 264.7 MW |
| Winter Capacity | 264.3 MW |
| Minimum Load | 131 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | July 2005 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 12H |
| Subcritical Technology | Yes |
| Multiple Fuels | No |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | No |
Generator 1CT1 Details Operating May 2008
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Combustion Turbine Part |
| Unit Code | PWG1 |
| Ownership | Wholly Owned by Other Entity |
| Can Bypass Heat Recovery Steam Generator | No |
| RTO ISO LMP Node Designation | WEC.PORTWA1CT1 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | WEC.PORTWA1CT1 |
| Nameplate Capacity | 173.1 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 178.2 MW |
| Winter Capacity | 207 MW |
| Minimum Load | 101 MW |
| Uprate/Derate Completed | No |
|---|---|
| Status | Operating |
| First Operation Date | May 2008 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 12H |
| Multiple Fuels | No |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | No |
Generator 1CT2 Details Operating May 2008
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Combustion Turbine Part |
| Unit Code | PWG1 |
| Ownership | Wholly Owned by Other Entity |
| Can Bypass Heat Recovery Steam Generator | No |
| RTO ISO LMP Node Designation | WEC.PORTWA1CT2 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | WEC.PORTWA1CT2 |
| Nameplate Capacity | 173.1 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 178.8 MW |
| Winter Capacity | 207 MW |
| Minimum Load | 101 MW |
| Uprate/Derate Completed | No |
|---|---|
| Status | Operating |
| First Operation Date | May 2008 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 12H |
| Multiple Fuels | No |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | No |
Generator ST1 Details Operating May 2008
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Steam Part |
| Unit Code | PWG1 |
| Ownership | Wholly Owned by Other Entity |
| Duct Burners | Yes |
| RTO ISO LMP Node Designation | WEC.PORTWA1ST0 |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | WEC.PORTWA1ST0 |
| Nameplate Capacity | 268.6 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 265.1 MW |
| Winter Capacity | 265.2 MW |
| Minimum Load | 131 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | May 2008 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 12H |
| Subcritical Technology | Yes |
| Multiple Fuels | No |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | No |
Port Washington Generating Station Plant Owners
| Owner Name | Address | Generator | Ownership |
|---|---|---|---|
| We Power | 231 W. Michigan Ave., Milwaukee, WI 53203 | Generator 1CT1 | 100.00% |
| We Power | 231 W. Michigan Ave., Milwaukee, WI 53203 | Generator 1CT2 | 100.00% |
| We Power | 231 W. Michigan Ave., Milwaukee, WI 53203 | Generator 2CT1 | 100.00% |
| We Power | 231 W. Michigan Ave., Milwaukee, WI 53203 | Generator 2CT2 | 100.00% |
| We Power | 231 W. Michigan Ave., Milwaukee, WI 53203 | Generator ST1 | 100.00% |
| We Power | 231 W. Michigan Ave., Milwaukee, WI 53203 | Generator ST2 | 100.00% |
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
| Rank | Plant Name | Plant Location | Annual Generation |
|---|---|---|---|
| #29 | Nine Mile Point | Westwego, LA | 7.9 TWh |
| #30 | Jackson Generation, LLC | Elwood, IL | 7.9 TWh |
| #31 | Victor J Daniel Jr | Escatawpa, MS | 9.7 TWh |
| #32 | Odessa-Ector Power Plant | Odessa, TX | 7.9 TWh |
| #33 | Fairless Energy Center | Fairless Hills, PA | 7.8 TWh |
| #34 | Seminole (FL) | Palatka, FL | 10.0 TWh |
| #35 | Hummel Station LLC | Shamokin Dam, PA | 7.5 TWh |
| #36 | Paradise | Drakesboro, KY | 7.5 TWh |
| #37 | Moxie Freedom Generation Plant | Salem Township, PA | 7.5 TWh |
| #38 | Wansley Combined Cycle | Franklin, GA | 7.5 TWh |
| #40 | New Covert Generating Facility | Covert, MI | 7.2 TWh |
| #41 | Big Bend | Apollo Beach, FL | 7.2 TWh |
| #42 | Temple Power Station | Temple, TX | 7.0 TWh |
| #43 | Riviera | Riviera Beach, FL | 6.9 TWh |
| #44 | Cape Canaveral | Cocoa, FL | 6.9 TWh |
| #45 | Magnolia Power Plant | Ashland, MS | 6.8 TWh |
| #46 | Tenaska Westmoreland Generating Station | Smithton, PA | 6.8 TWh |
| #47 | Jack County | Bridgeport, TX | 6.7 TWh |
| #48 | Lamar Power Project | Paris, TX | 6.7 TWh |
| #49 | Allen | Memphis, TN | 6.7 TWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Port Washington Generating Station.
| Plant Name | Plant Location | Annual Generation | Distance |
|---|---|---|---|
| ATI | Cudahy, WI | 3.5 GWh | 30.4 mi |
| Auburn Solar WI, LLC | Campbellsport, WI | 80.0 MWh | 23.8 mi |
| Butler Ridge | Mayville, WI | 140.2 GWh | 30.8 mi |
| Cedar Ridge | Eden, WI | 174.6 GWh | 31.4 mi |
| City of Milwaukee Landfill | Milwaukee, WI | 3.6 GWh | 31.1 mi |
| Edgewater | Sheboygan, WI | 2.0 TWh | 24.3 mi |
| Germantown | Germantown, WI | 28.1 GWh | 19.2 mi |
| Harley-Davison Powertrain Operations | Menomonee Falls, WI | 3.3 GWh | 18 mi |
| IKEA Oak Creek Rooftop PV System | Oak Creek, WI | 1.4 GWh | 33.4 mi |
| Jackson Solar WI, LLC | Cedarburg, WI | 3.7 GWh | 12.3 mi |
| Kohler Solar | Kohler, WI | 2.6 GWh | 25.6 mi |
| Lannon Stone | Pewaukee, WI | 3.7 GWh | 26.3 mi |
| MMSD Jones Island Wastewater | Milwaukee, WI | 74.1 GWh | 25.1 mi |
| Omega Hills Gas Recovery | Germantown, WI | 80.1 GWh | 19.7 mi |
| Onion River | Sheboygan Cedar Grove, WI | 252.6 GWh | 15 mi |
| Regal Ware | West Bend, WI | 2.8 GWh | 15.8 mi |
| Sheboygan Falls | Sheboygan, WI | 642.5 GWh | 25.4 mi |
| Springfield Solar (WI) | Lomira, WI | 202.6 GWh | 32.5 mi |
| Valley (WI) | Milwaukee, WI | 353.5 GWh | 24.6 mi |
| Washington County | West Bend, WI | 3.8 GWh | 15 mi |