Okeechobee Clean Energy Center
3193 NE 366th Trail, Okeechobee, FL 34972Plant Summary Information
Okeechobee Clean Energy Center is ranked #48 out of 12,613 power plants nationwide in terms of total annual net electricity generation.
Okeechobee Clean Energy Center is comprised of 4 generators and generated 3.2 TWh during the 3-month period between September 2025 to December 2025.
| Plant Name | Okeechobee Clean Energy Center |
|---|---|
| Utility Name | Florida Power & Light Co |
| Location | Okeechobee County, FL |
| Initial Operation Date | March 2019 |
| Last Update | Dec 2025 |
| Annual Generation | 12.0 TWh |
| Annual Consumption | 81.5 M MMBtu |
| Ranked #48 out of 12,613 Power Plants Nationwide | |
| Ranked #4 out of 2,246 Natural Gas Power Plants Nationwide | |
| Ranked #5 out of 325 Florida Power Plants | |
| Ranked #2 out of 81 Florida Natural Gas Power Plants | |
| Fuel Types | Natural Gas |
Map of Okeechobee Clean Energy Center
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Okeechobee Clean Energy Center.
Monthly Net Generation for Okeechobee Clean Energy Center
Monthly Plant Fuel Consumption for Okeechobee Clean Energy Center
Okeechobee Clean Energy Center Details
| Summary Information | |
|---|---|
| Plant Name | Okeechobee Clean Energy Center (60345) |
| Plant Address | 3193 NE 366th Trail, Okeechobee, FL 34972 |
| Utility | Florida Power & Light Co (6452) |
| Latitude, Longitude | 27.63417, -80.79111 |
| Generation Dates on File | Mar 2019 to Dec 2025 |
| Initial Operation Date | March 2019 |
| Annual Generation | 12.0 TWh |
| Fuel Types | Natural Gas |
| Federal Energy Regulatory Commission (FERC) Information | |
| FERC Cogeneration Status | No |
| FERC Small Power Producer Status | No |
| FERC Exempt Wholesale Generator Status | No |
| Regulatory Information | |
|---|---|
| Regulatory Status | Regulated |
| NERC Region | SERC |
| Balancing Authority | Florida Power & Light Company (FPL) |
| NAICS Code | Utilities (22) |
| Sector | Electric Utility (1) |
| Water Source | Upper Floridian Aquifer |
| Ash Impoundment | |
| Transmission / Distribution Owner | Florida Power & Light Co (6452) FL |
| Grid Voltage | 500.00 kV |
| Energy Storage | No |
| Natural Gas Information | |
| Local Distribution Company (LDC) | Other - See pipeline notes. |
| Pipeline Notes | Florida Southeast Connection |
Generator 1A Details Operating March 2019
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Combustion Turbine Part |
| Unit Code | CC1 |
| Ownership | Single Owner |
| Can Bypass Heat Recovery Steam Generator | No |
| Nameplate Capacity | 376.6 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 376.6 MW |
| Winter Capacity | 376.6 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | March 2019 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Hydrogen / Distillate Fuel Oil |
| Time From Cold Shutdown To Full Load | 12H |
| Multiple Fuels | Yes |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Switch When Operating | Yes |
|---|---|
| Net Summer Capacity With Natural Gas | 376.6 MW |
| Net Winter Capacity With Natural Gas | 376.6 MW |
| Net Summer Capacity With Oil | 325.3 MW |
| Net Winter Capacity With Oil | 346 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 1H |
| Factors That Limit Switching | Yes |
| Air Permit Limits | Yes |
Generator 1B Details Operating March 2019
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Combustion Turbine Part |
| Unit Code | CC1 |
| Ownership | Single Owner |
| Can Bypass Heat Recovery Steam Generator | No |
| Nameplate Capacity | 376.6 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 376.6 MW |
| Winter Capacity | 376.6 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | March 2019 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Time From Cold Shutdown To Full Load | 12H |
| Multiple Fuels | Yes |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Switch When Operating | Yes |
|---|---|
| Net Summer Capacity With Natural Gas | 376.6 MW |
| Net Winter Capacity With Natural Gas | 376.6 MW |
| Net Summer Capacity With Oil | 325.3 MW |
| Net Winter Capacity With Oil | 346 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 1H |
| Factors That Limit Switching | Yes |
| Air Permit Limits | Yes |
Generator 1C Details Operating March 2019
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Combustion Turbine Part |
| Unit Code | CC1 |
| Ownership | Single Owner |
| Can Bypass Heat Recovery Steam Generator | No |
| Nameplate Capacity | 376.6 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 376.6 MW |
| Winter Capacity | 376.6 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | March 2019 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Time From Cold Shutdown To Full Load | 12H |
| Multiple Fuels | Yes |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Switch When Operating | Yes |
|---|---|
| Net Summer Capacity With Natural Gas | 376.6 MW |
| Net Winter Capacity With Natural Gas | 376.6 MW |
| Net Summer Capacity With Oil | 325.3 MW |
| Net Winter Capacity With Oil | 346 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 1H |
| Factors That Limit Switching | Yes |
| Air Permit Limits | Yes |
Generator 1ST Details Operating March 2019
| Technology | Natural Gas Fired Combined Cycle |
|---|---|
| Prime Mover | Combined Cycle Steam Part |
| Unit Code | CC1 |
| Ownership | Single Owner |
| Duct Burners | No |
| Nameplate Capacity | 593.3 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 593.3 MW |
| Winter Capacity | 593.3 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | March 2019 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Time From Cold Shutdown To Full Load | 12H |
| Multiple Fuels | Yes |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Switch When Operating | Yes |
|---|---|
| Net Summer Capacity With Natural Gas | 531.1 MW |
| Net Winter Capacity With Natural Gas | 511 MW |
| Net Summer Capacity With Oil | 526.1 MW |
| Net Winter Capacity With Oil | 449 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 1H |
| Factors That Limit Switching | Yes |
| Air Permit Limits | Yes |
Okeechobee Clean Energy Center Plant Owners
| Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
|---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
| Rank | Plant Name | Plant Location | Annual Generation |
|---|---|---|---|
| #1 | West County Energy Center | Loxahatchee, FL | 18.7 TWh |
| #2 | Jack McDonough | Smyrna, GA | 17.5 TWh |
| #3 | H Allen Franklin Combined Cycle | Smiths, AL | 12.1 TWh |
| #5 | Barry | Bucks, AL | 12.5 TWh |
| #6 | Hines Energy Complex | Bartow, FL | 11.8 TWh |
| #7 | Crystal River | Crystal River, FL | 15.3 TWh |
| #8 | Greensville County Power Station | Emporia, VA | 11.3 TWh |
| #9 | Guernsey Power Station | Byesville, OH | 11.3 TWh |
| #10 | Hanging Rock Energy Facility | Ironton, OH | 10.2 TWh |
| #11 | Union Power Station | El Dorado, AR | 10.1 TWh |
| #12 | Forney Energy Center | Forney, TX | 10.0 TWh |
| #13 | Sherwood H Smith Jr Energy Complex | Hamlet, NC | 9.9 TWh |
| #14 | Brunswick County Power Station | Freeman, VA | 9.7 TWh |
| #15 | Midland Cogeneration Venture | Midland, MI | 9.6 TWh |
| #16 | Lackawanna Energy Center | Jessup, PA | 9.0 TWh |
| #17 | Fort Myers | Ft. Myers, FL | 9.0 TWh |
| #18 | York Energy Center | Delta, PA | 8.8 TWh |
| #19 | Warren County | Front Royal, VA | 8.7 TWh |
| #20 | Fairless Energy Center | Fairless Hills, PA | 8.5 TWh |
| #21 | Blue Water Energy Center | East China, MI | 8.4 TWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Okeechobee Clean Energy Center.
| Plant Name | Plant Location | Annual Generation | Distance |
|---|---|---|---|
| Barefoot Bay Solar Energy Center | Sebastian, FL | 135.8 GWh | 23 mi |
| Big Water | TBD, FL | 183.7 GWh | 13.3 mi |
| Blue Cypress Solar Energy Center | Vero Beach, FL | 131.3 GWh | 15.6 mi |
| Buttonwood | Fort Pierce, FL | 194.4 GWh | 9.4 mi |
| Fort Drum Energy Center | Vero Beach, FL | 137.9 GWh | 2.7 mi |
| Fox Trail | Callahan, FL | 181.4 GWh | 16.3 mi |
| FPL Cavendish Solar Energy Center | Okeechobee, FL | 116.1 GWh | 0.9 mi |
| Grove | Vero Beach, FL | 143.7 GWh | 9.2 mi |
| Honeybell | TBD, FL | 194.8 GWh | 9.3 mi |
| Ibis | Palm Bay, FL | 132.8 GWh | 15.9 mi |
| Indian River Solar Center | Vero Beach, FL | 137.9 GWh | 13.7 mi |
| Interstate Solar Energy Center | Ft. Pierce, FL | 135.1 GWh | 23.4 mi |
| Mallard | Palm Bay, FL | 3.8 GWh | 15.2 mi |
| Okeechobee Solar | Vero Beach, FL | 149.2 GWh | 0.3 mi |
| Orange Blossom Solar Center | Vero Beach, FL | 151.5 GWh | 13.7 mi |
| Orchard | Ft. Pierce, FL | 157.9 GWh | 14.5 mi |
| Palm Bay Solar | Palm Bay, FL | 150.3 GWh | 17.4 mi |
| Pelican Solar Center | Ft. Pierce, FL | 151.3 GWh | 16.8 mi |
| Speckled Perch | TBD, FL | 191.4 GWh | 24.6 mi |
| Turnpike | Vero Beach, FL | 171.1 GWh | 10.1 mi |