Los Angeles Refinery Wilmington

1660 W Anaheim St, Wilmington, CA 90744

Plant Summary Information

Los Angeles Refinery Wilmington is ranked #14 out of 61 other gas power plants nationwide in terms of total annual net electricity generation.

Los Angeles Refinery Wilmington is comprised of 1 generator and generated 101.0 GWh during the 3-month period between December 2024 to March 2025.

Plant NameLos Angeles Refinery Wilmington
Utility NamePhillips 66 - Los Angeles
LocationLos Angeles County, CA
Initial Operation DateMay 1984
Last Update Mar 2025
Annual Generation 398.2 GWh
Annual Consumption 5.4 M MMBtu
Ranked #1,547 out of 12,288 Power Plants Nationwide
Ranked #14 out of 61 Other Gas Power Plants Nationwide
Ranked #109 out of 1,564 California Power Plants
Ranked #3 out of 10 California Other Gas Power Plants
Fuel Types Other Gas : 55.8% Natural Gas : 44.2%

Map of Los Angeles Refinery Wilmington

Full Screen Map
Use Ctrl + scroll to zoom the map
Use two fingers to move the map

Register Now for Comprehensive Access

Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Los Angeles Refinery Wilmington.

Create Your Account Today

Monthly Net Generation for Los Angeles Refinery Wilmington

50k50k40k40k30k30k20k20k10k10k0020012001200220022003200320042004200520052006200620072007200820082009200920102010201120112012201220132013201420142015201520162016201720172018201820192019202020202021202120222022202320232024202420252025
Download SVG
Download PNG
Download CSV

Los Angeles Refinery Wilmington Details

Summary Information
Plant NameLos Angeles Refinery Wilmington (54451)
Plant Address1660 W Anaheim St, Wilmington, CA 90744
UtilityPhillips 66 - Los Angeles (38215)
Latitude, Longitude33.7686, -118.2867
Generation Dates on FileJan 2001 to Mar 2025
Initial Operation DateMay 1984
Annual Generation 398.2 GWh
Fuel Types Other Gas : 55.8% Natural Gas : 44.2%
 
Federal Energy Regulatory Commission (FERC) Information
FERC Cogeneration StatusYes
FERC Cogeneration Docket Number87-423-000
FERC Small Power Producer StatusNo
FERC Exempt Wholesale Generator StatusNo
Regulatory Information
Regulatory StatusNon-Regulated
NERC RegionWECC
Balancing AuthorityLos Angeles Department of Water and Power (LDWP)
NAICS CodePetroleum and Coal Products Manufacturing (324)
Sector Industrial CHP (7)
Water SourceMunicipality
Ash Impoundment No
Transmission / Distribution OwnerLos Angeles Department of Water & Power (11208) CA
Grid Voltage 34.50 kV
Energy StorageNo
 
Natural Gas Information
Local Distribution Company (LDC)SOUTHERN CALIFORNIA GAS COMPANY
Pipeline NotesPhillips 66 Wilmington Refinery is served by Southern California Gas Company Supply Line 43-34
Natural Gas StorageNo
Liquefied Natural Gas StorageNo

Generator G2 Details Operating May 1988

TechnologyOther Gases
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity58.5 MW
Nameplate Power Factor0.8
Summer Capacity50 MW
Winter Capacity52 MW
Minimum Load35 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 1988
Combined Heat & Power Yes
Sector NameIndustrial CHP (7)
Topping Or BottomingT
Energy SourceOther Gas / Natural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full LoadOVER
Pulverized Coal TechnologyNo
Multiple FuelsYes
Cofire FuelsYes
Switch Between Oil And Natural GasNo
Multifuel Details
Cofire Energy SourceOG / NG

Los Angeles Refinery Wilmington Plant Owners

Owner NameAddressOwnership
We couldn't locate any owners for this plant

Power Plants with Similar Net Generation

Power plants with a similar annual net generation from Other Gas.

RankPlant NamePlant LocationAnnual Generation
#4Equilon Los Angeles RefiningWilmington, CA368.3 GWh
#5Watson CogenerationCarson, CA2.4 TWh
#6Middletown Coke Company, LLCMiddletown, OH349.5 GWh
#7Haverhill North Cogeneration FacilityFranklin Furnace, OH353.4 GWh
#8Shute Creek FacilityKemmerer, WY830.9 GWh
#9ArcelorMittal Burns HarborBurns Harbor, IN922.0 GWh
#10Whiting RefineryWhiting, IN359.6 GWh
#11LaO Energy SystemsPlaquemine, LA1.8 TWh
#12HF Sinclair Puget Sound RefiningAnacortes, WA1.0 TWh
#13CITGO Refinery PowerhouseSulphur, LA226.1 GWh
#15Phillips 66 Rodeo RefineryRodeo, CA291.0 GWh
#16Delaware City PlantDelaware City, DE1.1 TWh
#17GeismarGeismar, LA514.1 GWh
#18Bayou Cogen PlantPasadena, TX2.1 TWh
#19ExxonMobil Oil Joliet RefineryChannahon, IL177.8 GWh
#20Black Hawk StationBorger, TX1.3 TWh
#21Motiva Enterprises Port Arthur RefineryPort Arthur, TX1.6 TWh
#22ExxonMobil Beaumont RefineryBeaumont, TX4.4 TWh
#23Paulsboro RefineryPaulsboro, NJ341.9 GWh
#24Shell Deer ParkDeer Park, TX1.3 TWh

Nearby Power Plants

Below are closest 20 power plants surrounding Los Angeles Refinery Wilmington.

Plant NamePlant LocationAnnual GenerationDistance
Alta SeaSan Pedro, CA3.0 GWh3.5 mi
Catalina ExpressSan Pedro, CA1.7 GWh1.4 mi
Colon PVWilmington, CA1.2 GWh2.6 mi
Equilon Los Angeles RefiningWilmington, CA368.3 GWh3.4 mi
HarborWilmington, CA235.4 GWh1.2 mi
Harbor CogenWilmington, CA17.4 GWh3.3 mi
Kaiser - Harbor CityHarbor City, CA17.9 GWh1.4 mi
KSR053 Cantara Fuel CellPanorama City, CA12.1 GWh1.6 mi
Los Angeles Harbor CollegeWilmington, CA2.5 GWh1 mi
Port of LA Solar FiT ProjectSan Pedro, CA1.5 GWh2.8 mi
Southeast Resource RecoveryLong Beach, CA89.9 GWh2.8 mi
Total Energy FacilitiesCarson, CA160.8 GWh0.2 mi
Valero Wilmington Cogeneration PlantWilmington, CA228.2 GWh2.9 mi
Westmont 300ASan Pedro, CA5.0 GWh0.2 mi
Westmont 300BSan Pedro, CA5.1 GWh0.2 mi
Westmont 301San Pedro, CA3.0 GWh0.4 mi
Westmont 400ALos Angeles, CA3.3 GWh0.3 mi
Westmont 400BLos Angeles, CA3.6 GWh0.3 mi
Westmont 401San Pedro, CA4.3 GWh0.4 mi
Wilmington Hydrogen PlantWilmington, CA136.0 GWh2.8 mi