Dahlberg

585 Jarrett Road, Nicholson, GA 30565

Plant Summary Information

Dahlberg is ranked #47 out of 246 power plants in Georgia in terms of total annual net electricity generation.

Dahlberg is comprised of 10 generators and generated 55.2 GWh during the 3-month period between September 2024 to December 2024.

Plant NameDahlberg
Utility NameSouthern Power Co
LocationJackson County, GA
Initial Operation DateJune 2000
Last Update Dec 2024
Annual Generation 229.4 GWh
Annual Consumption 3.1 M MMBtu
Ranked #2,220 out of 12,288 Power Plants Nationwide
Ranked #730 out of 2,221 Natural Gas Power Plants Nationwide
Ranked #47 out of 246 Georgia Power Plants
Ranked #14 out of 45 Georgia Natural Gas Power Plants
Fuel Types Natural Gas : 92.4% Distillate Fuel Oil : 7.6%

Map of Dahlberg

Full Screen Map
Use Ctrl + scroll to zoom the map
Use two fingers to move the map

Register Now for Comprehensive Access

Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Dahlberg.

Create Your Account Today

Monthly Net Generation for Dahlberg

100k100k80k80k60k60k40k40k20k20k00200120012002200220032003200420042005200520062006200720072008200820092009201020102011201120122012201320132014201420152015201620162017201720182018201920192020202020212021202220222023202320242024
Download SVG
Download PNG
Download CSV

Dahlberg Details

Summary Information
Plant NameDahlberg (7709)
Plant Address585 Jarrett Road, Nicholson, GA 30565
UtilitySouthern Power Co (17650)
Latitude, Longitude34.04227, -83.39772
Generation Dates on FileJan 2001 to Dec 2024
Initial Operation DateJune 2000
Annual Generation 229.4 GWh
Fuel Types Natural Gas : 92.4% Distillate Fuel Oil : 7.6%
 
Federal Energy Regulatory Commission (FERC) Information
FERC Cogeneration StatusNo
FERC Small Power Producer StatusNo
FERC Exempt Wholesale Generator StatusNo
Regulatory Information
Regulatory StatusNon-Regulated
NERC RegionSERC
Balancing AuthoritySouthern Company Services, Inc. - Trans (SOCO)
NAICS CodeUtilities (22)
Sector IPP Non-CHP (2)
Water Source
Ash Impoundment No
Transmission / Distribution OwnerGeorgia Power Co (7140) GA
Grid Voltage 230.00 kV
Energy StorageNo
 
Natural Gas Information
Pipeline Name TRANSCONTINENTAL GAS PIPELINE
Natural Gas StorageNo

Generator 1 Details Operating June 2000

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity74.8 MW
Winter Capacity87.1 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2000
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74.8 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil74.8 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Generator 2 Details Operating June 2000

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity74 MW
Winter Capacity87.4 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2000
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil74 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Generator 3 Details Operating June 2000

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity74.7 MW
Winter Capacity87.8 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2000
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74.7 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil74.7 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Generator 4 Details Operating June 2000

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity73.5 MW
Winter Capacity86.9 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2000
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas73.2 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil73.2 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Generator 5 Details Operating June 2000

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity74.7 MW
Winter Capacity87.7 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2000
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74.7 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil74.7 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Generator 7 Details Operating June 2000

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity75 MW
Winter Capacity88 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2000
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas75 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil75 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Generator 8 Details Operating June 2000

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity74 MW
Winter Capacity87 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 2000
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil74 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Generator 6 Details Operating July 2000

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity74.9 MW
Winter Capacity87.7 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJuly 2000
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas74.9 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil74.9 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Generator 10 Details Operating May 2001

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity75.2 MW
Winter Capacity88.6 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 2001
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas75.2 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil75.2 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Generator 9 Details Operating May 2001

TechnologyNatural Gas Fired Combustion Turbine
Prime MoverCombustion Turbine
OwnershipSingle Owner
Nameplate Capacity91.9 MW
Nameplate Power Factor0.85
Summer Capacity74.8 MW
Winter Capacity88 MW
Minimum Load70 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 2001
Combined Heat & Power No
Sector NameIPP Non-CHP (2)
Energy SourceNatural Gas / Distillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load1H
Multiple FuelsYes
Cofire FuelsNo
Switch Between Oil And Natural GasYes
Multifuel Details
Switch When OperatingYes
Net Summer Capacity With Natural Gas76.1 MW
Net Winter Capacity With Natural Gas89 MW
Net Summer Capacity With Oil76.1 MW
Net Winter Capacity With Oil89 MW
Time To Switch From Gas To Oil6H
Time To Switch From Oil To Gas6H
Factors That Limit SwitchingNo

Dahlberg Plant Owners

Owner NameAddressGeneratorOwnership
We couldn't locate any owners for this plant

Power Plants with Similar Net Generation

Power plants with a similar annual net generation from Natural Gas.

RankPlant NamePlant LocationAnnual Generation
#720E W BrownHarrodsburg, KY1.6 TWh
#721University of California San Diego HybriLa Jolla, CA220.4 GWh
#722Roseton Generating FacilityNewsburgh, NY283.2 GWh
#723Kimberly Clark-Unit 1,2,3New Milford, CT219.0 GWh
#724El Dorado RefineryEl Dorado, KS217.7 GWh
#725Exelon West Medway II LLCMedway, MA221.0 GWh
#726Ingredion IncorporatedBedford Park, IL216.2 GWh
#727Central Utility Plant CincinnatiCincinnati, OH217.3 GWh
#728Kern River Eastridge CogenBakersfield, CA215.1 GWh
#729Saguaro PowerHenderson, NV213.3 GWh
#731Charles D. Lamb Energy CenterPonca City, OK211.8 GWh
#732Calvert CityCalvert City, KY210.9 GWh
#733Walnut Creek Energy ParkIndustry, CA209.6 GWh
#734Limon Generating StationLimon, CO216.3 GWh
#735University of Illinois Abbott Power PltChampaign, IL211.1 GWh
#736Mass Inst Tech Cntrl Utilities/Cogen PltCambridge, MA204.8 GWh
#737University of MichiganAnn Arbor, MI203.7 GWh
#738Cass CountyPlattsmouth, NE202.4 GWh
#739Smarr Energy CenterForsyth, GA202.0 GWh
#740Paulsboro RefineryPaulsboro, NJ341.9 GWh

Nearby Power Plants

Below are closest 20 power plants surrounding Dahlberg.

Plant NamePlant LocationAnnual GenerationDistance
Cedar Creek Solar, LLCWinder, GA3.6 GWh20.6 mi
CII Methane Management III LFG PlantWinterville, GA3.9 GWh11.1 mi
Comer SolarComer, GA3.5 GWh15 mi
Doyle Energy FacilityMonroe, GA30.6 GWh22.3 mi
Franklin MillikenLavonia, GA6.5 GWh32.5 mi
Georgia LFG Oak Grove PlantWinder, GA38.7 GWh21.7 mi
Georgia LFG Richland Creek PlantBuford, GA54.1 GWh36.8 mi
Gratis Road Solar FacilityMonroe, GA5.3 GWh21.9 mi
Greene DurhamUnion Point, GA6.6 GWh33.3 mi
GRP Franklin Renewable Energy FacilityCarnesville, GA398.9 GWh23.4 mi
GRP Madison Renewable Energy FacilityColbert, GA395.6 GWh11.7 mi
Hartwell Energy FacilityHartwell, GA174.9 GWh38.9 mi
Mount Vernon SolarMonroe, GA1.8 GWh19.7 mi
MPC GeneratingMonroe, GA38.8 GWh23.3 mi
Pleasant Valley SolarMonroe, GA4.3 GWh27.2 mi
Simon Solar Farm LLCSocial Circle, GA47.5 GWh29.8 mi
Sonny Solar LLCElberton, GA89.1 GWh38.7 mi
Tallassee Hydro ProjectClarke, GA4.1 GWh6.8 mi
Walton County Energy FacilityMonroe, GA313.8 GWh23.2 mi
Wolfskin SolarArnoldsville, GA23.6 GWh14.1 mi