Turners Falls
I Street, Montague, MA 1376Plant Summary Information
Turners Falls is ranked #15 out of 28 hydroelectric power plants in Massachusetts in terms of total annual net electricity generation.
Turners Falls is comprised of 5 generators and generated 715.0 MWh during the 3-month period between September 2024 to December 2024.
| Plant Name | Turners Falls |
|---|---|
| Utility Name | FirstLight Power Resources, Inc. - MA |
| Location | Franklin County, MA |
| Initial Operation Date | January 1905 |
| Last Update | Dec 2024 |
| Annual Generation | 12.4 GWh |
| Annual Consumption | 51.6 k MMBtu |
| Ranked #5,819 out of 12,539 Power Plants Nationwide | |
| Ranked #883 out of 1,332 Water Power Plants Nationwide | |
| Ranked #61 out of 629 Massachusetts Power Plants | |
| Ranked #15 out of 28 Massachusetts Water Power Plants | |
| Fuel Types | Water |
Map of Turners Falls
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Turners Falls.
Monthly Net Generation for Turners Falls
Turners Falls Details
| Summary Information | |
|---|---|
| Plant Name | Turners Falls (6388) |
| Plant Address | I Street, Montague, MA 1376 |
| Utility | FirstLight Power Resources, Inc. - MA (58185) |
| Latitude, Longitude | 42.60804, -72.56146 |
| Generation Dates on File | Jan 2001 to Dec 2024 |
| Initial Operation Date | January 1905 |
| Annual Generation | 12.4 GWh |
| Fuel Types | Water |
| Federal Energy Regulatory Commission (FERC) Information | |
| FERC Cogeneration Status | No |
| FERC Small Power Producer Status | No |
| FERC Exempt Wholesale Generator Status | Yes |
| FERC Exempt Wholesale Generator Docket Number | 00-94-000 |
| Regulatory Information | |
|---|---|
| Regulatory Status | Non-Regulated |
| NERC Region | NPCC |
| Balancing Authority | ISO New England Inc. (ISNE) |
| NAICS Code | Utilities (22) |
| Sector | IPP Non-CHP (2) |
| Water Source | Connecticut River |
| Ash Impoundment | No |
| Transmission / Distribution Owner | Western Massachusetts Electric Company (20455) MA |
| Grid Voltage | 13.80 kV |
| Energy Storage | No |
Generator 5 Details Operating January 1905
| Technology | Conventional Hydroelectric |
|---|---|
| Prime Mover | Hydroelectric Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | N.MONTAGUE13.8TURN |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | N.MONTAGUE13.8TURN |
| Nameplate Capacity | 1.3 MW |
| Nameplate Power Factor | 1 |
| Summer Capacity | 1.4 MW |
| Winter Capacity | 1.4 MW |
| Minimum Load | 1.3 MW |
| Uprate/Derate Completed | No |
|---|---|
| Status | Operating |
| First Operation Date | January 1905 |
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Water |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | No |
Generator 3 Details Operating January 1910
| Technology | Conventional Hydroelectric |
|---|---|
| Prime Mover | Hydroelectric Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | N.MONTAGUE13.8TURN |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | N.MONTAGUE13.8TURN |
| Nameplate Capacity | 1.3 MW |
| Nameplate Power Factor | 1 |
| Summer Capacity | 1.3 MW |
| Winter Capacity | 1.3 MW |
| Minimum Load | 1.3 MW |
| Uprate/Derate Completed | No |
|---|---|
| Status | Operating |
| First Operation Date | January 1910 |
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Water |
| Solid Fuel Gasification | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | No |
Generator 7 Details Operating January 1910
| Technology | Conventional Hydroelectric |
|---|---|
| Prime Mover | Hydroelectric Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | N.MONTAGUE13.8TURN |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | N.MONTAGUE13.8TURN |
| Nameplate Capacity | 1.3 MW |
| Nameplate Power Factor | 1 |
| Summer Capacity | 1.4 MW |
| Winter Capacity | 1.4 MW |
| Minimum Load | 1.3 MW |
| Uprate/Derate Completed | No |
|---|---|
| Status | Operating |
| First Operation Date | January 1910 |
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Water |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | No |
Generator 1 Details Operating January 1913
| Technology | Conventional Hydroelectric |
|---|---|
| Prime Mover | Hydroelectric Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | N.MONTAGUE13.8TURN |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | N.MONTAGUE13.8TURN |
| Nameplate Capacity | 1.4 MW |
| Nameplate Power Factor | 1 |
| Summer Capacity | 1.9 MW |
| Winter Capacity | 1.9 MW |
| Minimum Load | 0.9 MW |
| Uprate/Derate Completed | No |
|---|---|
| Status | Operating |
| First Operation Date | January 1913 |
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Water |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | No |
Generator 2 Details Operating January 1913
| Technology | Conventional Hydroelectric |
|---|---|
| Prime Mover | Hydroelectric Turbine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | N.MONTAGUE13.8TURN |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | N.MONTAGUE13.8TURN |
| Nameplate Capacity | 0.4 MW |
| Nameplate Power Factor | 1 |
| Summer Capacity | 0.4 MW |
| Winter Capacity | 0.4 MW |
| Minimum Load | 0.4 MW |
| Uprate/Derate Completed | No |
|---|---|
| Status | Operating |
| First Operation Date | January 1913 |
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Water |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | No |
Turners Falls Plant Owners
| Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
|---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Water.
| Rank | Plant Name | Plant Location | Annual Generation |
|---|---|---|---|
| #873 | Apple River | Somerset, WI | 13.0 GWh |
| #874 | Mine Falls Generating Station | Nashua, NH | 12.7 GWh |
| #875 | Nacoochee | Lakemont, GA | 12.6 GWh |
| #876 | Frankenheimer Power Plant | Oakdale, CA | 12.6 GWh |
| #877 | Birch Creek Power | Terreton, ID | 12.6 GWh |
| #878 | Lachute Hydro Lower | Ticonderoga, NY | 12.6 GWh |
| #879 | Lachute Hydro Upper | Ticonderoga, NY | 12.6 GWh |
| #880 | White River Lock and Dam 2 | Locust Grove, AR | 12.6 GWh |
| #881 | Petersburg | Petersburg, AK | 13.0 GWh |
| #882 | Schoolfield Dam | Danville, VA | 12.5 GWh |
| #884 | Allegan Dam | Allegan, MI | 12.3 GWh |
| #885 | Waterport | Waterport, NY | 12.3 GWh |
| #886 | Lake Mendocino | Ukiah, CA | 12.3 GWh |
| #887 | Purple Lake | Metlakatla, AK | 12.3 GWh |
| #888 | White River Lock and Dam 1 | Batesville, AR | 12.3 GWh |
| #889 | Deer Creek PH | Nevada City, CA | 12.1 GWh |
| #890 | Lower Molina | Molina, CO | 12.1 GWh |
| #891 | Dillon Hydro Plant | Summit, CO | 12.1 GWh |
| #892 | Hampshire Paper | Gouverneur, NY | 12.1 GWh |
| #893 | Franklin (NY) | Franklin, NY | 12.1 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Turners Falls.
| Plant Name | Plant Location | Annual Generation | Distance |
|---|---|---|---|
| Axio Green LLC | Greenfield Township, MA | 2.5 GWh | 3.3 mi |
| Cabot | Montague, MA | 304.2 GWh | 1.7 mi |
| Deerfield 2 | Conway, MA | 29.2 GWh | 7.8 mi |
| Deerfield 3 | Buckland, MA | 25.0 GWh | 8.8 mi |
| Deerfield 4 | Buckland, MA | 20.2 GWh | 9 mi |
| Deerfield CSG Solar | Deerfield, MA | 6.3 GWh | 3.4 mi |
| Erving CSG | Erving, MA | 1.5 GWh | 4.6 mi |
| Erving Paper Mills | Erving, MA | 41.7 GWh | 8.9 mi |
| Fairview Farms Solar | Whately, MA | 2.9 GWh | 10.5 mi |
| French King Solar LLC | Erving, MA | 7.8 GWh | 3.8 mi |
| Gardners Falls | Buckland, MA | 11.1 GWh | 8.7 mi |
| Greenfield Solar PV | Greenfield, MA | 2.9 GWh | 2.4 mi |
| Kearsarge Gill | Gill, MA | 3.1 GWh | 6.1 mi |
| Kearsarge Montague | Montague, MA | 7.2 GWh | 1.5 mi |
| Kearsarge Montague BD(CSG) | Montague, MA | 3.4 GWh | 1.5 mi |
| Montague Site 36-Grosolar | Millers Falls, MA | 5.9 GWh | 8.1 mi |
| NFM Solar Power LLC | Northfield, MA | 1.9 GWh | 4.4 mi |
| Old Frontier Solar III | South Deerfield, MA | 4.1 GWh | 8.5 mi |
| Wendell MA 1 | Wendell, MA | 1.4 GWh | 8.9 mi |
| Wilbur Woods Solar LLC | Orange, MA | 8.3 GWh | 11 mi |