Princeton (IL)
1 North Main, Princeton, IL 61356Plant Summary Information
Princeton (IL) is ranked #56 out of 64 natural gas power plants in Illinois in terms of total annual net electricity generation.
Princeton (IL) is comprised of 8 generators and generated 201.0 MWh during the 3-month period between September 2025 to December 2025.
| Plant Name | Princeton (IL) |
|---|---|
| Utility Name | City of Princeton - (IL) |
| Location | Bureau County, IL |
| Initial Operation Date | July 1953 |
| Last Update | Dec 2025 |
| Annual Generation | 813.0 MWh |
| Annual Consumption | 2.5 M MMBtu |
| Ranked #12,090 out of 13,081 Power Plants Nationwide | |
| Ranked #1,876 out of 2,206 Natural Gas Power Plants Nationwide | |
| Ranked #413 out of 483 Illinois Power Plants | |
| Ranked #56 out of 64 Illinois Natural Gas Power Plants | |
| Fuel Types | Natural Gas : 99.8% |
Map of Princeton (IL)
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Princeton (IL).
Monthly Net Generation for Princeton (IL)
Monthly Plant Fuel Consumption for Princeton (IL)
Princeton (IL) Details
| Summary Information | |
|---|---|
| Plant Name | Princeton (IL) (957) |
| Plant Address | 1 North Main, Princeton, IL 61356 |
| Utility | City of Princeton - (IL) (15388) |
| Latitude, Longitude | 41.37553, -89.46487 |
| Generation Dates on File | Jan 2001 to Dec 2025 |
| Initial Operation Date | July 1953 |
| Annual Generation | 813.0 MWh |
| Fuel Types | Natural Gas : 99.8% |
| Federal Energy Regulatory Commission (FERC) Information | |
| FERC Cogeneration Status | No |
| FERC Small Power Producer Status | No |
| FERC Exempt Wholesale Generator Status | No |
| Regulatory Information | |
|---|---|
| Regulatory Status | Regulated |
| NERC Region | SERC |
| Balancing Authority | Midcontinent Independent Transmission System Operator, Inc.. (MISO) |
| NAICS Code | Utilities (22) |
| Sector | Electric Utility (1) |
| Water Source | Municipality |
| Ash Impoundment | No |
| Transmission / Distribution Owner | City of Princeton - (IL) (15388) IL |
| Grid Voltage | 138.00 kV |
| Energy Storage | No |
| Natural Gas Information | |
| Local Distribution Company (LDC) | NICOR GAS |
| Pipeline Notes | Only connected to the LDC |
| Natural Gas Storage | No |
| Liquefied Natural Gas Storage | No |
Generator 1 Details Operating July 1953
| Technology | Natural Gas Internal Combustion Engine |
|---|---|
| Prime Mover | Internal Combustion Engine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | AMIL.IP.IMEA |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | AMIL.IP.IMEA |
| Nameplate Capacity | 2.3 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 2.3 MW |
| Winter Capacity | 2.3 MW |
| Minimum Load | 0.5 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | July 1953 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 10M |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | DFO / NG |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 2.3 MW |
| Net Winter Capacity With Natural Gas | 2.3 MW |
| Net Summer Capacity With Oil | 2.3 MW |
| Net Winter Capacity With Oil | 2.3 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 6H |
| Factors That Limit Switching | No |
Generator 2 Details Operating April 1958
| Technology | Natural Gas Internal Combustion Engine |
|---|---|
| Prime Mover | Internal Combustion Engine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | AMIL.IP.IMEA |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | AMIL.IP.IMEA |
| Nameplate Capacity | 3 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 3 MW |
| Winter Capacity | 3 MW |
| Minimum Load | 1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | April 1958 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 10M |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | DFO / NG |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 3 MW |
| Net Winter Capacity With Natural Gas | 3 MW |
| Net Summer Capacity With Oil | 3 MW |
| Net Winter Capacity With Oil | 3 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 6H |
| Factors That Limit Switching | No |
Generator 4 Details Operating January 1965
| Technology | Natural Gas Internal Combustion Engine |
|---|---|
| Prime Mover | Internal Combustion Engine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | AMIL.IP.IMEA |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | AMIL.IP.IMEA |
| Nameplate Capacity | 3.4 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 3.4 MW |
| Winter Capacity | 3.4 MW |
| Minimum Load | 1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | January 1965 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | DFO / NG |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 3.4 MW |
| Net Winter Capacity With Natural Gas | 3.4 MW |
| Net Summer Capacity With Oil | 3.4 MW |
| Net Winter Capacity With Oil | 3.4 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 6H |
| Factors That Limit Switching | No |
Generator 3 Details Operating August 1965
| Technology | Natural Gas Internal Combustion Engine |
|---|---|
| Prime Mover | Internal Combustion Engine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | AMIL.IP.IMEA |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | AMIL.IP.IMEA |
| Nameplate Capacity | 3.4 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 3.4 MW |
| Winter Capacity | 3.4 MW |
| Minimum Load | 1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | August 1965 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | DFO / NG |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 3.4 MW |
| Net Winter Capacity With Natural Gas | 3.4 MW |
| Net Summer Capacity With Oil | 3.4 MW |
| Net Winter Capacity With Oil | 3.4 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 6H |
| Factors That Limit Switching | No |
Generator 5 Details Operating July 1971
| Technology | Natural Gas Internal Combustion Engine |
|---|---|
| Prime Mover | Internal Combustion Engine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | AMIL.IP.IMEA |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | AMIL.IP.IMEA |
| Nameplate Capacity | 4.4 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 4.4 MW |
| Winter Capacity | 4.4 MW |
| Minimum Load | 1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | July 1971 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | DFO / NG |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 4.4 MW |
| Net Winter Capacity With Natural Gas | 4.4 MW |
| Net Summer Capacity With Oil | 4.4 MW |
| Net Winter Capacity With Oil | 4.4 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 6H |
| Factors That Limit Switching | No |
Generator 6 Details Operating August 1971
| Technology | Natural Gas Internal Combustion Engine |
|---|---|
| Prime Mover | Internal Combustion Engine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | AMIL.IP.IMEA |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | AMIL.IP.IMEA |
| Nameplate Capacity | 5.6 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 5.5 MW |
| Winter Capacity | 5.5 MW |
| Minimum Load | 1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | August 1971 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | DFO / NG |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 5.5 MW |
| Net Winter Capacity With Natural Gas | 5.5 MW |
| Net Summer Capacity With Oil | 5.5 MW |
| Net Winter Capacity With Oil | 5.5 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 6H |
| Factors That Limit Switching | No |
Generator 7 Details Operating September 1976
| Technology | Natural Gas Internal Combustion Engine |
|---|---|
| Prime Mover | Internal Combustion Engine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | AMIL.IP.IMEA |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | AMIL.IP.IMEA |
| Nameplate Capacity | 7 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 7 MW |
| Winter Capacity | 7 MW |
| Minimum Load | 1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | September 1976 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | DFO / NG |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 7 MW |
| Net Winter Capacity With Natural Gas | 7 MW |
| Net Summer Capacity With Oil | 7 MW |
| Net Winter Capacity With Oil | 7 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 6H |
| Factors That Limit Switching | No |
Generator 8 Details Operating September 1976
| Technology | Natural Gas Internal Combustion Engine |
|---|---|
| Prime Mover | Internal Combustion Engine |
| Ownership | Single Owner |
| RTO ISO LMP Node Designation | AMIL.IP.IMEA |
| RTO ISO Location Designation For Reporting Wholesale Sales Data | AMIL.IP.IMEA |
| Nameplate Capacity | 8.8 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 8.7 MW |
| Winter Capacity | 8.7 MW |
| Minimum Load | 1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | September 1976 |
| Combined Heat & Power | No |
| Sector Name | Electric Utility (1) |
| Energy Source | Natural Gas / Distillate Fuel Oil |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | DFO / NG |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 8.7 MW |
| Net Winter Capacity With Natural Gas | 8.7 MW |
| Net Summer Capacity With Oil | 8.7 MW |
| Net Winter Capacity With Oil | 8.7 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 6H |
| Factors That Limit Switching | No |
Princeton (IL) Plant Owners
| Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
|---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
| Rank | Plant Name | Plant Location | Annual Generation |
|---|---|---|---|
| #1866 | SPI Anderson 2 | Anderson, CA | 122.1 GWh |
| #1867 | Coxsackie | Coxsackie, NY | 1.1 GWh |
| #1868 | FTBLID2 | Sugarland, TX | 882.0 MWh |
| #1869 | Springs Generating Station | Riverside, CA | 878.0 MWh |
| #1870 | HEBCCBakery | Corpus Christi, TX | 866.0 MWh |
| #1871 | HEB_CPSSADC | San Antonio, TX | 862.0 MWh |
| #1872 | Charles P Keller | Rockville Centre, NY | 1.0 GWh |
| #1873 | Encina Water Pollution Control | Carlsbad, CA | 14.3 GWh |
| #1874 | Riley Generating Station | Zeeland, MI | 844.0 MWh |
| #1875 | Red Wing | Red Wing, MN | 131.9 GWh |
| #1877 | Coit GT | Columbia, SC | 2.0 GWh |
| #1878 | SB Water Reclamation Fuel Cell | San Bernardino, CA | 9.4 GWh |
| #1879 | Augusta Electric Plant No 2 | Augusta, KS | 832.0 MWh |
| #1880 | Woodland Biomass Power Ltd | Woodland, CA | 161.9 GWh |
| #1881 | Mora | Mora, MN | 1.1 GWh |
| #1882 | Holton | City of Holton, KS | 806.0 MWh |
| #1883 | Hillburn | Hillburn, NY | 701.0 MWh |
| #1884 | Port Townsend Paper | Port Townsend, WA | 7.7 GWh |
| #1885 | Pasco Cnty Solid Waste Resource Recovery | Spring Hill, FL | 186.1 GWh |
| #1886 | Pinellas County Resource Recovery | St. Petersburg, FL | 222.5 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Princeton (IL).
| Plant Name | Plant Location | Annual Generation | Distance |
|---|---|---|---|
| Agriwind | Tiskilwa, IL | 16.7 GWh | 9.7 mi |
| Big Sky Wind LLC | Ohio, IL | 816.6 GWh | 15.5 mi |
| Bureau Solar 1 | Princeton, IL | 2.3 GWh | 4.7 mi |
| Camp Grove Wind Farm | Wyoming, IL | 406.1 GWh | 21.7 mi |
| City of Peru Plank Road Generating Station | Peru, IL | 20.6 GWh | 17 mi |
| City of Peru Rail Generating Station | Peru, IL | 53.0 MWh | 17.5 mi |
| City of Peru Water Street Generating Sta | Peru, IL | 33.0 MWh | 18 mi |
| Com Adam 1WF-1 | Sublette, IL | 7.0 GWh | 22.6 mi |
| Crescent Ridge | Tiskilwa, IL | 199.2 GWh | 10.3 mi |
| DePue Holdings, LLC | DePue, IL | 35.0 GWh | 8.9 mi |
| Green River Wind Farm | Deer Grove, IL | 497.3 GWh | 17.6 mi |
| Lone Tree Wind, LLC | Tiskilwa, IL | 281.5 GWh | 13.9 mi |
| Mendota | Mendota, IL | 3.3 GWh | 19.8 mi |
| Mendota Rich Dev CSG | Mendota, IL | 4.1 GWh | 20 mi |
| Princeton Solar | Princeton, IL | 903.9 MWh | 1.7 mi |
| Providence Heights Wind LLC | Tiskilwa, IL | 134.8 GWh | 11.2 mi |
| Putnam Solar 1 | Granville, IL | 3.6 GWh | 15.5 mi |
| Putnam Solar 1B | Granville, IL | 4.0 GWh | 15.4 mi |
| Rocky Mountain Elk Solar Community Solar | Sheffield, IL | 108.0 MWh | 11.4 mi |
| Walnut Ridge Wind Farm | Sheffield, IL | 772.2 GWh | 10.3 mi |