Arthur Kill Generating Station
4401 Victory Blvd, Staten Island, NY 10314Plant Summary Information
Arthur Kill Generating Station is ranked #19 out of 944 power plants in New York in terms of total annual net electricity generation.
Arthur Kill Generating Station is comprised of 3 generators and generated 602.9 GWh during the 3-month period between June 2025 to September 2025.
| Plant Name | Arthur Kill Generating Station |
|---|---|
| Utility Name | NRG Arthur Kill Operations Inc |
| Location | Richmond County, NY |
| Initial Operation Date | September 1959 |
| Last Update | Sep 2025 |
| Annual Generation | 2.1 TWh |
| Annual Consumption | 23.4 M MMBtu |
| Ranked #502 out of 12,539 Power Plants Nationwide | |
| Ranked #306 out of 2,243 Natural Gas Power Plants Nationwide | |
| Ranked #19 out of 944 New York Power Plants | |
| Ranked #14 out of 115 New York Natural Gas Power Plants | |
| Fuel Types | Natural Gas |
Map of Arthur Kill Generating Station
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Arthur Kill Generating Station.
Monthly Net Generation for Arthur Kill Generating Station
Arthur Kill Generating Station Details
| Summary Information | |
|---|---|
| Plant Name | Arthur Kill Generating Station (2490) |
| Plant Address | 4401 Victory Blvd, Staten Island, NY 10314 |
| Utility | NRG Arthur Kill Operations Inc (13192) |
| Latitude, Longitude | 40.59156, -74.20004 |
| Generation Dates on File | Jan 2001 to Sep 2025 |
| Initial Operation Date | September 1959 |
| Annual Generation | 2.1 TWh |
| Fuel Types | Natural Gas |
| Federal Energy Regulatory Commission (FERC) Information | |
| FERC Cogeneration Status | No |
| FERC Small Power Producer Status | No |
| FERC Exempt Wholesale Generator Status | Yes |
| FERC Exempt Wholesale Generator Docket Number | 99-165-000 |
| Regulatory Information | |
|---|---|
| Regulatory Status | Non-Regulated |
| NERC Region | NPCC |
| Balancing Authority | New York Independent System Operator (NYIS) |
| NAICS Code | Utilities (22) |
| Sector | IPP Non-CHP (2) |
| Water Source | Arthur Kill |
| Ash Impoundment | No |
| Transmission / Distribution Owner | Consolidated Edison Co-NY Inc (4226) NY |
| Grid Voltage | 138.00 kV / 345.00 kV |
| Energy Storage | No |
| Natural Gas Information | |
| Local Distribution Company (LDC) | CONSOLIDATED EDISON NEW YORK INC |
| Natural Gas Storage | No |
| Liquefied Natural Gas Storage | No |
Generator 2 Details Operating September 1959
| Technology | Natural Gas Steam Turbine |
|---|---|
| Prime Mover | Steam Turbine |
| Ownership | Wholly Owned by Other Entity |
| Nameplate Capacity | 342 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 363.2 MW |
| Winter Capacity | 359.2 MW |
| Minimum Load | 90 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
| First Operation Date | September 1959 |
| Combined Heat & Power | No |
|---|---|
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Natural Gas |
| Startup Source | Natural Gas |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | OVER |
| Multiple Fuels | No |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | No |
Generator 3 Details Operating June 1969
| Technology | Natural Gas Steam Turbine |
|---|---|
| Prime Mover | Steam Turbine |
| Ownership | Wholly Owned by Other Entity |
| Nameplate Capacity | 535.5 MW |
| Nameplate Power Factor | 0.9 |
| Summer Capacity | 520.4 MW |
| Winter Capacity | 523.3 MW |
| Minimum Load | 150 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
| First Operation Date | June 1969 |
| Combined Heat & Power | No |
|---|---|
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Natural Gas |
| Startup Source | Natural Gas |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | OVER |
| Multiple Fuels | No |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | No |
Generator GT1 Details Operating January 1970
| Technology | Natural Gas Fired Combustion Turbine |
|---|---|
| Prime Mover | Combustion Turbine |
| Ownership | Wholly Owned by Other Entity |
| Nameplate Capacity | 18 MW |
| Nameplate Power Factor | 1 |
| Summer Capacity | 12.4 MW |
| Winter Capacity | 16.1 MW |
| Minimum Load | 1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
| First Operation Date | January 1970 |
|---|---|
| Combined Heat & Power | No |
| Sector Name | IPP Non-CHP (2) |
| Energy Source | Natural Gas |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 10M |
| Multiple Fuels | No |
| Cofire Fuels | No |
| Switch Between Oil And Natural Gas | No |
Arthur Kill Generating Station Plant Owners
| Owner Name | Address | Generator | Ownership |
|---|---|---|---|
| Arthur Kill Power LLC | 4401 Victory Blvd, Staten Island, NY 10314 | Generator 2 | 100.00% |
| Arthur Kill Power LLC | 4401 Victory Blvd, Staten Island, NY 10314 | Generator 3 | 100.00% |
| Arthur Kill Power LLC | 4401 Victory Blvd, Staten Island, NY 10314 | Generator GT1 | 100.00% |
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Natural Gas.
| Rank | Plant Name | Plant Location | Annual Generation |
|---|---|---|---|
| #296 | Colorado Bend Energy Center | Wharton, TX | 2.2 TWh |
| #297 | Rolling Hills Generating | Wilkesville, OH | 2.2 TWh |
| #298 | Greater Des Moines | Pleasant Hill, IA | 2.2 TWh |
| #299 | Bayou Cogen Plant | Pasadena, TX | 2.4 TWh |
| #300 | State Line Combined Cycle | Joplin, MO | 2.2 TWh |
| #301 | Magic Valley Generating Station | Edinburg, TX | 2.2 TWh |
| #302 | AES Huntington Beach Energy Project | Huntington Beach, CA | 2.1 TWh |
| #303 | Anclote | Holiday, FL | 2.1 TWh |
| #304 | Goldendale Generating Station | Goldendale, WA | 2.1 TWh |
| #305 | Yates | Newnan, GA | 2.1 TWh |
| #307 | Louisiana 1 | Baton Rouge, LA | 2.9 TWh |
| #308 | Chesterfield | Chester, VA | 2.1 TWh |
| #309 | Sand Hill | Austin, TX | 2.1 TWh |
| #310 | Coyote Springs | Boardman, OR | 2.0 TWh |
| #311 | South Point Energy Center | Mohave Valley, AZ | 2.0 TWh |
| #312 | PSEG Sewaren Generating Station | Sewaren, NJ | 2.0 TWh |
| #313 | Harrington | Amarillo, TX | 2.3 TWh |
| #314 | Frontera Energy Center | Mission, TX | 2.0 TWh |
| #315 | Hay Road | Wilmington, DE | 2.0 TWh |
| #316 | Desert Basin | Casa Grande, AZ | 2.0 TWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Arthur Kill Generating Station.
| Plant Name | Plant Location | Annual Generation | Distance |
|---|---|---|---|
| Amazon | Carteret, NJ | 3.9 GWh | 2.1 mi |
| Amazon JFK8 Solar Project | Staten Island, NY | 6.9 GWh | 2 mi |
| Apple Staten Island - Industrial Loop | Staten Island, NY | 12.8 GWh | 3.2 mi |
| Bayway Refinery | Linden, NJ | 69.6 GWh | 3.4 mi |
| Bed Bath & Beyond DC Port Reading NJ | Port Reading, NJ | 2.2 GWh | 2.7 mi |
| Certain Solar - Staten Island | Staten Island, NY | 16.4 GWh | 3.7 mi |
| DG Infineum | Linden, NJ | 2.5 GWh | 3.8 mi |
| Fuel Cell 18A Sneden Avenue | Staten Island, NY | 27.3 GWh | 3.7 mi |
| Fuel Cell 18B Sneden Avenue | Staten Island, NY | 31.7 GWh | 3.7 mi |
| IGS Solar I - EWR5 | Avenel, NJ | 3.6 GWh | 3 mi |
| IGS Solar I - EWR6 | Avenel, NJ | 3.3 GWh | 3 mi |
| IOS - ERW9 | Carteret, NJ | 6.9 GWh | 1.3 mi |
| Linden Cogen Plant | Linden, NJ | 5.7 TWh | 2.9 mi |
| Linden Hawk Rise Solar CSG | Linden, NJ | 6.2 GWh | 2.5 mi |
| Linden Solar Farm | Linden, NJ | 4.1 GWh | 2.1 mi |
| Merck Rahway Power Plant | Rahway, NJ | 33.4 GWh | 3.8 mi |
| Port Reading 8 Solar | Carteret, NJ | 2.0 GWh | 2.1 mi |
| PSEG Linden Generating Station | Linden, NJ | 4.8 TWh | 2.1 mi |
| PSEG Sewaren Generating Station | Sewaren, NJ | 2.0 TWh | 3.5 mi |
| Union County Resource Recovery | Rahway, NJ | 288.3 GWh | 3.5 mi |