Sappi Cloquet Mill
2201 Avenue B, Cloquet, MN 55720Plant Summary Information
Sappi Cloquet Mill is ranked #14 out of 80 black liquor power plants nationwide in terms of total annual net electricity generation.
Sappi Cloquet Mill is comprised of 7 generators and generated 116.4 GWh during the 3-month period between July 2025 to October 2025.
| Plant Name | Sappi Cloquet Mill |
|---|---|
| Utility Name | Sappi Cloquet LLC |
| Location | Carlton County, MN |
| Initial Operation Date | January 1929 |
| Last Update | Oct 2025 |
| Annual Generation | 449.5 GWh |
| Annual Consumption | 15.6 M MMBtu |
| Ranked #1,457 out of 12,553 Power Plants Nationwide | |
| Ranked #14 out of 80 Black Liquor Power Plants Nationwide | |
| Ranked #22 out of 759 Minnesota Power Plants | |
| Ranked #1 out of 2 Minnesota Black Liquor Power Plants | |
| Fuel Types | Black Liquor : 64.8% Wood/Wood Waste Solids : 17.9% Natural Gas : 13.1% Water : 3.5% |
Map of Sappi Cloquet Mill
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Sappi Cloquet Mill.
Monthly Net Generation for Sappi Cloquet Mill
Sappi Cloquet Mill Details
| Summary Information | |
|---|---|
| Plant Name | Sappi Cloquet Mill (50639) |
| Plant Address | 2201 Avenue B, Cloquet, MN 55720 |
| Utility | Sappi Cloquet LLC (16653) |
| Latitude, Longitude | 46.7243, -92.4298 |
| Generation Dates on File | Jan 2001 to Oct 2025 |
| Initial Operation Date | January 1929 |
| Annual Generation | 449.5 GWh |
| Fuel Types | Black Liquor : 64.8% Wood/Wood Waste Solids : 17.9% Natural Gas : 13.1% Water : 3.5% |
| Federal Energy Regulatory Commission (FERC) Information | |
| FERC Cogeneration Status | Yes |
| FERC Cogeneration Docket Number | 85-706-000; '85-706-001; '02-061-000 |
| FERC Small Power Producer Status | Yes |
| FERC Small Power Producer Docket Number | 02-363-007 |
| FERC Exempt Wholesale Generator Status | No |
| Regulatory Information | |
|---|---|
| Regulatory Status | Non-Regulated |
| NERC Region | MRO |
| Balancing Authority | Midcontinent Independent Transmission System Operator, Inc.. (MISO) |
| NAICS Code | (322122) |
| Sector | Industrial CHP (7) |
| Water Source | Lake Superior |
| Ash Impoundment | No |
| Transmission / Distribution Owner | ALLETE, Inc. (12647) MN |
| Grid Voltage | 115.00 kV |
| Energy Storage | No |
| Natural Gas Information | |
| Local Distribution Company (LDC) | MINNESOTA ENERGY RESOURCES |
| Natural Gas Storage | No |
Generator HGN5 Details Operating January 1929
| Technology | Conventional Hydroelectric |
|---|---|
| Prime Mover | Hydroelectric Turbine |
| Ownership | Single Owner |
| Nameplate Capacity | 0.8 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 0.5 MW |
| Winter Capacity | 0.5 MW |
| Minimum Load | 0.1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | January 1929 |
| Combined Heat & Power | No |
| Sector Name | Industrial CHP (7) |
| Energy Source | Water |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
Generator HGN6 Details Operating January 1929
| Technology | Conventional Hydroelectric |
|---|---|
| Prime Mover | Hydroelectric Turbine |
| Ownership | Single Owner |
| Nameplate Capacity | 0.8 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 0.5 MW |
| Winter Capacity | 0.5 MW |
| Minimum Load | 0.1 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | January 1929 |
| Combined Heat & Power | No |
| Sector Name | Industrial CHP (7) |
| Energy Source | Water |
| Solid Fuel Gasification | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | No |
Generator HGN1 Details Operating January 1950
| Technology | Conventional Hydroelectric |
|---|---|
| Prime Mover | Hydroelectric Turbine |
| Ownership | Single Owner |
| Nameplate Capacity | 1.8 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 1.6 MW |
| Winter Capacity | 1.6 MW |
| Minimum Load | 0.5 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | January 1950 |
| Combined Heat & Power | No |
| Sector Name | Industrial CHP (7) |
| Energy Source | Water |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | 1H |
Generator GEN3 Details Operating January 1976
| Technology | Wood/Wood Waste Biomass |
|---|---|
| Prime Mover | Steam Turbine |
| Ownership | Single Owner |
| Nameplate Capacity | 19.2 MW |
| Nameplate Power Factor | 0.9 |
| Summer Capacity | 17.5 MW |
| Winter Capacity | 17.5 MW |
| Minimum Load | 8 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
| First Operation Date | January 1976 |
| Combined Heat & Power | Yes |
|---|---|
| Sector Name | Industrial CHP (7) |
| Topping Or Bottoming | T |
| Energy Source | Wood/Wood Waste Solids / Natural Gas / Sludge Waste / Distillate Fuel Oil / Black Liquor |
| Startup Source | Wood/Wood Waste Solids |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | OVER |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | BLQ / NG / WDS / SLW / DFO |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 14.8 MW |
| Net Winter Capacity With Natural Gas | 14.8 MW |
| Net Summer Capacity With Oil | 17.5 MW |
| Net Winter Capacity With Oil | 17.5 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 1H |
| Factors That Limit Switching | No |
Generator HGN7 Details Operating January 1980
| Technology | Conventional Hydroelectric |
|---|---|
| Prime Mover | Hydroelectric Turbine |
| Ownership | Single Owner |
| Nameplate Capacity | 2.8 MW |
| Nameplate Power Factor | 0.8 |
| Summer Capacity | 1 MW |
| Winter Capacity | 1.4 MW |
| Minimum Load | 0.5 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
|---|---|
| First Operation Date | January 1980 |
| Combined Heat & Power | No |
| Sector Name | Industrial CHP (7) |
| Energy Source | Water |
| Solid Fuel Gasification | No |
| Time From Cold Shutdown To Full Load | 1H |
| Multiple Fuels | No |
Generator GEN4 Details Operating December 1997
| Technology | Wood/Wood Waste Biomass |
|---|---|
| Prime Mover | Steam Turbine |
| Ownership | Single Owner |
| Nameplate Capacity | 41.5 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 41.5 MW |
| Winter Capacity | 41.5 MW |
| Minimum Load | 6 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
| First Operation Date | December 1997 |
| Combined Heat & Power | Yes |
|---|---|
| Sector Name | Industrial CHP (7) |
| Topping Or Bottoming | T |
| Energy Source | Wood/Wood Waste Solids / Natural Gas / Sludge Waste / Distillate Fuel Oil / Black Liquor |
| Startup Source | Wood/Wood Waste Solids |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | OVER |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | Yes |
| Multifuel Details | |
| Cofire Energy Source | BLQ / NG / WDS / SLW / DFO |
|---|---|
| Switch When Operating | Yes |
| Net Summer Capacity With Natural Gas | 41.5 MW |
| Net Winter Capacity With Natural Gas | 41.5 MW |
| Net Summer Capacity With Oil | 41.5 MW |
| Net Winter Capacity With Oil | 41.5 MW |
| Time To Switch From Gas To Oil | 1H |
| Time To Switch From Oil To Gas | 1H |
| Factors That Limit Switching | No |
Generator GEN5 Details Operating May 2001
| Technology | Wood/Wood Waste Biomass |
|---|---|
| Prime Mover | Steam Turbine |
| Ownership | Single Owner |
| Nameplate Capacity | 27.6 MW |
| Nameplate Power Factor | 0.85 |
| Summer Capacity | 14 MW |
| Winter Capacity | 15 MW |
| Minimum Load | 4 MW |
| Uprate/Derate Completed | No |
| Status | Operating |
| First Operation Date | May 2001 |
| Combined Heat & Power | Yes |
|---|---|
| Sector Name | Industrial CHP (7) |
| Topping Or Bottoming | T |
| Energy Source | Black Liquor / Natural Gas |
| Startup Source | Black Liquor |
| Solid Fuel Gasification | No |
| Carbon Capture Technology | No |
| Time From Cold Shutdown To Full Load | OVER |
| Multiple Fuels | Yes |
| Cofire Fuels | Yes |
| Switch Between Oil And Natural Gas | No |
| Multifuel Details | |
| Cofire Energy Source | BLQ / NG |
|---|---|
Sappi Cloquet Mill Plant Owners
| Owner Name | Address | Generator | Ownership | We couldn't locate any owners for this plant |
|---|
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Black Liquor.
| Rank | Plant Name | Plant Location | Annual Generation |
|---|---|---|---|
| #4 | Sylvamo Corporation Eastover Facility | Eastover, SC | 536.1 GWh |
| #5 | Alabama Pine Pulp | Perdue Hill, AL | 400.0 GWh |
| #6 | International Paper Prattville Mill | Prattville, AL | 582.0 GWh |
| #7 | Jesup Plant | Jesup, GA | 466.5 GWh |
| #8 | Flint River Operations | Oglethorpe, GA | 433.9 GWh |
| #9 | Leaf River Cellulose LLC | New Augusta, MS | 415.9 GWh |
| #10 | Covington Facility | Covington, VA | 728.8 GWh |
| #11 | Fernandina Beach Mill | Fernandina Beach, FL | 591.4 GWh |
| #12 | Mead Coated Board | Mahrt, AL | 732.3 GWh |
| #13 | International Paper Georgetown Mill | Georgetown, SC | 484.7 GWh |
| #15 | International Paper Riegelwood Mill | Riegelwood, NC | 340.9 GWh |
| #16 | Georgia-Pacific Brewton Mill | Brewton, AL | 499.4 GWh |
| #17 | Clearwater Paper IPP Lewiston | Lewiston, ID | 456.3 GWh |
| #18 | Mansfield Mill | Mansfield, LA | 842.9 GWh |
| #19 | Port Wentworth Mill | Port Wentworth, GA | 421.0 GWh |
| #20 | Georgia-Pacific Monticello Paper | Monticello, MS | 550.2 GWh |
| #21 | International Paper Pine Hill Mill | Pine Hill, AL | 475.7 GWh |
| #22 | Somerset Plant | Skowhegan, ME | 562.3 GWh |
| #23 | Packaging Corp of America | Counce, TN | 432.0 GWh |
| #24 | Georgia-Pacific Consr Prods LP-Naheola | Pennington, AL | 446.5 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding Sappi Cloquet Mill.
| Plant Name | Plant Location | Annual Generation | Distance |
|---|---|---|---|
| Clam River Dam | Danbury, WI | 5.1 GWh | 54 mi |
| Danbury Dam | Danbury, WI | 2.6 GWh | 50.1 mi |
| Fond Du Lac | Duluth, MN | 54.3 GWh | 7.6 mi |
| Grand Casino Hinckley Solar | Hinckley, MN | 5.6 GWh | 54.6 mi |
| Hibbing | Hibbing, MN | 35.9 GWh | 54.2 mi |
| Jean Duluth Solar | Duluth, MN | 2.2 GWh | 20.6 mi |
| Knife Falls | Cloquet, MN | 9.8 GWh | 0.9 mi |
| Laskin Solar | Hoyt Lakes, MN | 8.1 GWh | 56.4 mi |
| M L Hibbard | Duluth, MN | 99.1 GWh | 13.2 mi |
| Moose Lake | Moose Lake, MN | 63.0 MWh | 24.4 mi |
| MP CSG 1 LLC | Wrenshall, MN | 1.7 GWh | 7.5 mi |
| Prairie River | Grand Rapids, MN | 1.8 GWh | 63.6 mi |
| Rapids Energy Center | Grand Rapids, MN | 40.2 GWh | 63 mi |
| Scanlon | Scanlon, MN | 6.9 GWh | 1.1 mi |
| Spooner Solar Array | Spooner, WI | 3.6 GWh | 61.9 mi |
| Syl Laskin | Hoyt Lakes, MN | 172.0 GWh | 57.1 mi |
| Taconite Ridge 1 Wind Energy Center | Mountain Iron, MN | 47.4 GWh | 59.2 mi |
| Thomson | Carlton, MN | 290.5 GWh | 6.6 mi |
| Trego | Hayward, WI | 6.5 GWh | 59.5 mi |
| USS Itasca Clean Energy Solar LLC | Grand Rapids, MN | 3.6 GWh | 61.3 mi |