National Energy of Lincoln
509 West State Rd, Lincoln, MI 48742Plant Summary Information
National Energy of Lincoln is ranked #4 out of 10 wood/wood waste solids power plants in Michigan in terms of total annual net electricity generation.
National Energy of Lincoln is comprised of 1 generator and generated 21.3 GWh during the 3-month period between March 2024 to June 2024.
Plant Name | National Energy of Lincoln |
---|---|
Utility Name | National Salvage & Service Corporation |
Location | Alcona County, MI |
Initial Operation Date | January 1989 |
Last Update | Jun 2024 |
Annual Generation | 130.2 GWh |
Annual Consumption | 1.9 M MMBtu |
Ranked #2,951 out of 12,288 Power Plants Nationwide | |
Ranked #58 out of 155 Wood/Wood Waste Solids Power Plants Nationwide | |
Ranked #70 out of 258 Michigan Power Plants | |
Ranked #4 out of 10 Michigan Wood/Wood Waste Solids Power Plants | |
Fuel Types | Wood/Wood Waste Solids : 81.0% Tire-derived Fuels : 18.9% |
Previous Operator |
Viking Energy Corp (2013 to 2021) National Salvage & Service Corporation (2022 to 2024) |
Map of National Energy of Lincoln
Full Screen MapRegister Now for Comprehensive Access
Subscribe now to access all power plant data, utility information, FERC EQR data, and more for National Energy of Lincoln.
Monthly Net Generation for National Energy of Lincoln
National Energy of Lincoln Details
Summary Information | |
---|---|
Plant Name | National Energy of Lincoln (50772) |
Plant Address | 509 West State Rd, Lincoln, MI 48742 |
Utility | National Salvage & Service Corporation (19781) |
Latitude, Longitude | 44.68, -83.4167 |
Generation Dates on File | Jan 2001 to Jun 2024 |
Initial Operation Date | January 1989 |
Annual Generation | 130.2 GWh |
Fuel Types | Wood/Wood Waste Solids : 81.0% Tire-derived Fuels : 18.9% |
Federal Energy Regulatory Commission (FERC) Information | |
FERC Cogeneration Status | No |
FERC Small Power Producer Status | Yes |
FERC Small Power Producer Docket Number | 84-349-005 |
FERC Exempt Wholesale Generator Status | No |
Regulatory Information | |
---|---|
Regulatory Status | Non-Regulated |
NERC Region | RFC |
Balancing Authority | Midcontinent Independent Transmission System Operator, Inc.. (MISO) |
NAICS Code | Utilities (22) |
Sector | IPP Non-CHP (2) |
Water Source | Wells |
Ash Impoundment | No |
Transmission / Distribution Owner | ITC Transmission (56068) MI |
Grid Voltage | 138.00 kV |
Energy Storage | No |
Natural Gas Information | |
Local Distribution Company (LDC) | CONSUMERS ENERGY COMPANY |
Natural Gas Storage | No |
Generator GEN1 Details Operating January 1989
Technology | Wood/Wood Waste Biomass |
---|---|
Prime Mover | Steam Turbine |
Ownership | Wholly Owned by Other Entity |
Nameplate Capacity | 20 MW |
Nameplate Power Factor | 0.9 |
Summer Capacity | 16.3 MW |
Winter Capacity | 18 MW |
Minimum Load | 10 MW |
Uprate/Derate Completed | No |
Status | Operating |
First Operation Date | January 1989 |
Combined Heat & Power | No |
---|---|
Sector Name | IPP Non-CHP (2) |
Energy Source | Wood/Wood Waste Solids / Tire-derived Fuels / Natural Gas |
Startup Source | Natural Gas |
Solid Fuel Gasification | No |
Carbon Capture Technology | No |
Time From Cold Shutdown To Full Load | 12H |
Multiple Fuels | Yes |
Cofire Fuels | Yes |
Switch Between Oil And Natural Gas | No |
Multifuel Details | |
Cofire Energy Source | WDS / TDF / NG |
---|
National Energy of Lincoln Plant Owners
Owner Name | Address | Ownership |
---|---|---|
National Energy of Lincoln LLC | 509 West Traverse Bay Road, Lincoln, MI 48742 | 100.00% |
Power Plants with Similar Net Generation
Power plants with a similar annual net generation from Wood/Wood Waste Solids.
Rank | Plant Name | Plant Location | Annual Generation |
---|---|---|---|
#48 | Seneca Sustainable Energy LLC | Eugene, OR | 125.7 GWh |
#49 | St Paul Cogeneration | St. Paul, MN | 151.1 GWh |
#50 | Covington Facility | Covington, VA | 739.5 GWh |
#51 | National Energy of McBain | McBain, MI | 136.0 GWh |
#52 | Florence Mill | Florence, SC | 322.9 GWh |
#53 | Multitrade Rabun Gap, LLC | Rabun Gap, GA | 115.8 GWh |
#54 | Dillard Complex | Dillard, OR | 114.0 GWh |
#55 | Georgia-Pacific Cedar Springs | Cedar Springs, GA | 533.5 GWh |
#56 | Humboldt Sawmill Company | Scotia, CA | 111.2 GWh |
#57 | Fernandina Beach Mill | Fernandina Beach, FL | 588.8 GWh |
#59 | Port Wentworth Mill | Port Wentworth, GA | 421.0 GWh |
#60 | Escanaba Mill | Escanaba, MI | 456.1 GWh |
#61 | Rio Bravo Fresno | Fresno, CA | 108.4 GWh |
#62 | WestRock (TX) | Evadale, TX | 406.8 GWh |
#63 | Clearwater Paper IPP Lewiston | Lewiston, ID | 389.8 GWh |
#64 | John H Warden | L'Anse, MI | 110.6 GWh |
#65 | Genesee Power Station LP | Flint, MI | 96.5 GWh |
#66 | Sierra Pacific Burney Facility | Burney, CA | 96.3 GWh |
#67 | International Paper Pensacola | Cantonment, FL | 343.9 GWh |
#68 | Packaging Corp of America | Counce, TN | 422.6 GWh |
Nearby Power Plants
Below are closest 20 power plants surrounding National Energy of Lincoln.
Plant Name | Plant Location | Annual Generation | Distance |
---|---|---|---|
Alcona | Glennie, MI | 25.5 GWh | 20.7 mi |
Alpena Cement Plant | Alpena, MI | 181.9 GWh | 26.9 mi |
Apple Blossom Wind Farm | Pigeon, MI | 266.2 GWh | 60 mi |
Cooke | Oscoda, MI | 24.9 GWh | 16.2 mi |
Decorative Panels Intl | Alpena, MI | 42.9 GWh | 26.5 mi |
Deerfield Wind Energy 2 | Port Hope, MI | 326.2 GWh | 58.4 mi |
Deerfield Wind Energy, LLC | Kinde, MI | 501.2 GWh | 57.1 mi |
Echo Wind Park | Elkton, MI | 583.8 GWh | 56.5 mi |
Five Channels | Oscoda, MI | 23.2 GWh | 20.1 mi |
Foote | Oscoda, MI | 27.1 GWh | 16.9 mi |
Four Mile Hydropower Project | Alpena, MI | 9.0 GWh | 28.9 mi |
Harvest | Elkton, MI | 115.8 GWh | 59.6 mi |
Harvest 2 | Elkton, MI | 201.8 GWh | 58.3 mi |
Lightfoot Solar, LLC | Luzerne, MI | 548.0 MWh | 37.2 mi |
Loud | Oscoda, MI | 16.7 GWh | 21.2 mi |
McKinley Wind Park | Pigeon, MI | 53.1 GWh | 56.5 mi |
Mio | Mio, MI | 13.6 GWh | 35.2 mi |
Ninth Street Hydropower Project | Alpena, MI | 6.7 GWh | 27.1 mi |
Norway Point Hydropower Project | Alpena, MI | 15.3 GWh | 29.6 mi |
Pinconning White Feather | Pinconning, MI | 16.7 GWh | 60.1 mi |