Grand Coulee

n/a, Grand Coulee, WA 99133

Plant Summary Information

Grand Coulee is ranked #33 out of 11,455 power plants nationwide in terms of total annual net electricity generation.

Grand Coulee is comprised of 33 generators and generated 4.9 TWh during the 3-month period between November 2023 to February 2024.

Plant NameGrand Coulee
Utility NameU S Bureau of Reclamation
LocationGrant County, WA
Initial Operation DateMarch 1941
Last Update Feb 2024
Annual Generation 16.4 TWh
Annual Consumption 56.1 M MMBtu
Ranked #33 out of 11,455 Power Plants Nationwide
Ranked #2 out of 1,374 Water Power Plants Nationwide
Ranked #1 out of 133 Washington Power Plants
Ranked #1 out of 69 Washington Water Power Plants
Fuel Types Water

Map of Grand Coulee

Full Screen Map

Register Now for Comprehensive Access

Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Grand Coulee.

Create Your Account Today

Monthly Net Generation for Grand Coulee

Grand Coulee Details

Summary Information
Plant NameGrand Coulee (6163)
Plant Address Grand Coulee, WA 99133
UtilityU S Bureau of Reclamation (2518)
Latitude, Longitude47.95751, -118.97732
Generation Dates on FileJan 2001 to Feb 2024
Initial Operation DateMarch 1941
Annual Generation 16.4 TWh
Fuel Types Water
 
Federal Energy Regulatory Commission (FERC) Information
FERC Cogeneration StatusNo
FERC Small Power Producer StatusNo
FERC Exempt Wholesale Generator StatusNo
Regulatory Information
Regulatory StatusRegulated
NERC RegionWECC
Balancing AuthorityBonneville Power Administration (BPAT)
NAICS CodeUtilities (22)
Sector Electric Utility (1)
Water SourceColumbia River
Ash Impoundment No
Transmission / Distribution OwnerBonneville Power Administration (1738) WA
Grid Voltage 525.00 kV
Energy StorageYes

Generator LS1 Details Operating March 1941

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity10 MW
Nameplate Power Factor1
Summer Capacity10 MW
Winter Capacity10 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMarch 1941
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator LS2 Details Operating March 1941

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity10 MW
Nameplate Power Factor1
Summer Capacity10 MW
Winter Capacity10 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMarch 1941
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 3 Details Operating September 1941

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateSeptember 1941
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 2 Details Operating January 1942

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJanuary 1942
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 1 Details Operating April 1942

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateApril 1942
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 5 Details Operating November 1943

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateNovember 1943
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 8 Details Operating February 1943

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateFebruary 1943
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 6 Details Operating August 1943

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateAugust 1943
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 4 Details Operating February 1944

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateFebruary 1944
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 7 Details Operating October 1947

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateOctober 1947
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 9 Details Operating April 1948

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateApril 1948
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 18 Details Operating May 1949

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 1949
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 17 Details Operating July 1949

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJuly 1949
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 16 Details Operating September 1949

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateSeptember 1949
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 13 Details Operating October 1950

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateOctober 1950
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 15 Details Operating April 1950

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateApril 1950
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 14 Details Operating July 1950

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJuly 1950
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator LS3 Details Operating January 1951

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity10 MW
Nameplate Power Factor1
Summer Capacity10 MW
Winter Capacity10 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJanuary 1951
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 12 Details Operating April 1951

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateApril 1951
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 11 Details Operating June 1951

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 1951
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 10 Details Operating September 1951

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity125 MW
Nameplate Power Factor1
Summer Capacity125 MW
Winter Capacity125 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateSeptember 1951
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator PG7 Details Operating October 1973

TechnologyHydroelectric Pumped Storage
Prime MoverPumped Storage
OwnershipSingle Owner
Nameplate Capacity50 MW
Nameplate Power Factor1
Summer Capacity50 MW
Winter Capacity50 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateOctober 1973
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator PG8 Details Operating November 1973

TechnologyHydroelectric Pumped Storage
Prime MoverPumped Storage
OwnershipSingle Owner
Nameplate Capacity50 MW
Nameplate Power Factor1
Summer Capacity50 MW
Winter Capacity50 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateNovember 1973
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 19 Details Operating September 1975

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity600 MW
Nameplate Power Factor0.98
Summer Capacity690 MW
Winter Capacity690 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateSeptember 1975
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 21 Details Operating December 1976

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity600 MW
Nameplate Power Factor0.98
Summer Capacity690 MW
Winter Capacity690 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateDecember 1976
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 20 Details Operating April 1976

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity600 MW
Nameplate Power Factor0.98
Summer Capacity690 MW
Winter Capacity690 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateApril 1976
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 22 Details Operating May 1978

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity805 MW
Nameplate Power Factor0.98
Summer Capacity805 MW
Winter Capacity805 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 1978
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 23 Details Operating November 1979

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity805 MW
Nameplate Power Factor0.98
Summer Capacity805 MW
Winter Capacity805 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateNovember 1979
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator 24 Details Operating May 1980

TechnologyConventional Hydroelectric
Prime MoverHydroelectric Turbine
OwnershipSingle Owner
Nameplate Capacity805 MW
Nameplate Power Factor0.98
Summer Capacity805 MW
Winter Capacity805 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 1980
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator PG11 Details Operating November 1983

TechnologyHydroelectric Pumped Storage
Prime MoverPumped Storage
OwnershipSingle Owner
Nameplate Capacity53.5 MW
Nameplate Power Factor1
Summer Capacity53.5 MW
Winter Capacity53.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateNovember 1983
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator PG9 Details Operating April 1983

TechnologyHydroelectric Pumped Storage
Prime MoverPumped Storage
OwnershipSingle Owner
Nameplate Capacity53.5 MW
Nameplate Power Factor1
Summer Capacity53.5 MW
Winter Capacity53.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateApril 1983
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator PG10 Details Operating June 1983

TechnologyHydroelectric Pumped Storage
Prime MoverPumped Storage
OwnershipSingle Owner
Nameplate Capacity53.5 MW
Nameplate Power Factor1
Summer Capacity53.5 MW
Winter Capacity53.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJune 1983
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Generator PG12 Details Operating April 1984

TechnologyHydroelectric Pumped Storage
Prime MoverPumped Storage
OwnershipSingle Owner
Nameplate Capacity53.5 MW
Nameplate Power Factor1
Summer Capacity53.5 MW
Winter Capacity53.5 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateApril 1984
Combined Heat & Power No
Sector NameElectric Utility (1)
Energy SourceWater
Time From Cold Shutdown To Full Load10M

Grand Coulee Plant Owners

Owner NameAddressGeneratorOwnership
We couldn't locate any owners for this plant

Power Plants with Similar Net Generation

Power plants with a similar annual net generation from Water.

RankPlant NamePlant LocationAnnual Generation
#1Robert Moses NiagaraLewiston, NY17.1 TWh
#3Chief JosephBridgeport, WA9.8 TWh
#4Robert Moses Power DamMassena, NY7.7 TWh
#5John DayRufus, OR7.3 TWh
#6The DallesThe Dalles, OR5.9 TWh
#7Rocky ReachWenatchee, WA5.2 TWh
#8McNaryUmatilla, OR5.1 TWh
#9WanapumBeverly, WA4.3 TWh
#10Priest RapidsMattawa, WA4.1 TWh
#11BonnevilleCascade Locks, OR4.0 TWh
#12Glen Canyon DamPage, AZ3.7 TWh
#13WellsPateros, WA3.7 TWh
#14BoundaryMetaline, WA3.1 TWh
#15Wilson DamMuscle Shoals, AL2.4 TWh
#16OahePierre, SD2.3 TWh
#17LibbyLibby, MT2.2 TWh
#18ShastaRedding, CA2.2 TWh
#19Rock IslandWenatchee, WA2.1 TWh
#20DworshakAhsahka, ID2.1 TWh
#21ConowingoDarlington, MD2.0 TWh

Nearby Power Plants

Below are closest 20 power plants surrounding Grand Coulee.

Plant NamePlant LocationAnnual GenerationDistance
Adams Nielson SolarLind, WA38.3 GWh71.2 mi
ChelanWenatchee, WA465.1 GWh48.7 mi
Chief JosephBridgeport, WA9.8 TWh30.8 mi
Kettle Falls Generating StationKettle Falls, WA343.8 GWh60.7 mi
Little Falls (WA)Ford, WA229.2 GWh50 mi
Long LakeFord, WA548.0 GWh53.5 mi
Main Canal HeadworksCoulee City, WA117.5 GWh27.9 mi
Meyers FallsKettle Falls, WA9.5 GWh61 mi
Monroe StreetSpokane, WA107.6 GWh75.2 mi
Nine MileNine Mile, WA164.5 GWh68 mi
Northeast (WA)Spokane, WA1.2 GWh76.1 mi
PEC HeadworksMoses Lake, WA18.4 GWh69.8 mi
Quincy ChuteQuincy, WA32.8 GWh68.6 mi
Rattlesnake FlatRitzville, WA377.9 GWh72.8 mi
Rock IslandWenatchee, WA2.1 TWh66.9 mi
Rocky ReachWenatchee, WA5.2 TWh67.9 mi
Spokane Waste to EnergySpokane, WA137.7 GWh72.1 mi
Summer Falls Power PlantCoulee City, WA442.3 GWh34.7 mi
Upper FallsSpokane, WA70.4 GWh75.3 mi
WellsPateros, WA3.7 TWh41.1 mi