Franklin Heating Station

119 3rd Street SW, Rochester, MN 55902

Plant Summary Information

Franklin Heating Station is ranked #19 out of 53 natural gas power plants in Minnesota in terms of total annual net electricity generation.

Franklin Heating Station is comprised of 11 generators and generated 17.5 GWh during the 3-month period between December 2024 to March 2025.

Plant NameFranklin Heating Station
Utility NameFranklin Heating Station
LocationOlmsted County, MN
Initial Operation DateJanuary 1951
Last Update Mar 2025
Annual Generation 64.5 GWh
Annual Consumption 1.4 M MMBtu
Ranked #3,688 out of 12,288 Power Plants Nationwide
Ranked #1,095 out of 2,221 Natural Gas Power Plants Nationwide
Ranked #73 out of 756 Minnesota Power Plants
Ranked #19 out of 53 Minnesota Natural Gas Power Plants
Fuel Types Natural Gas : 75.9% Purchased Steam : 22.5% Distillate Fuel Oil : 1.6%

Map of Franklin Heating Station

Full Screen Map
Use Ctrl + scroll to zoom the map
Use two fingers to move the map

Register Now for Comprehensive Access

Subscribe now to access all power plant data, utility information, FERC EQR data, and more for Franklin Heating Station.

Create Your Account Today

Monthly Net Generation for Franklin Heating Station

8k8k6k6k4k4k2k2k0020012001200220022003200320042004200520052006200620072007200820082009200920102010201120112012201220132013201420142015201520162016201720172018201820192019202020202021202120222022202320232024202420252025
Download SVG
Download PNG
Download CSV

Franklin Heating Station Details

Summary Information
Plant NameFranklin Heating Station (54224)
Plant Address119 3rd Street SW, Rochester, MN 55902
UtilityFranklin Heating Station (6738)
Latitude, Longitude44.02058, -92.4656
Generation Dates on FileJan 2001 to Mar 2025
Initial Operation DateJanuary 1951
Annual Generation 64.5 GWh
Fuel Types Natural Gas : 75.9% Purchased Steam : 22.5% Distillate Fuel Oil : 1.6%
 
Federal Energy Regulatory Commission (FERC) Information
FERC Cogeneration StatusNo
FERC Small Power Producer StatusNo
FERC Exempt Wholesale Generator StatusNo
Regulatory Information
Regulatory StatusNon-Regulated
NERC RegionMRO
Balancing AuthorityMidcontinent Independent Transmission System Operator, Inc.. (MISO)
NAICS CodeHospitals (622)
Sector Commercial CHP (5)
Water SourceWell, Municipality
Ash Impoundment No
Transmission / Distribution OwnerRochester Public Utilities (16181) MN
Grid Voltage 13.80 kV
Energy StorageNo
 
Natural Gas Information
Local Distribution Company (LDC)MINNESOTA ENERGY RESOURCES
Natural Gas StorageNo
Liquefied Natural Gas StorageNo

Generator GEN1 Details Operating January 1951

TechnologyNatural Gas Steam Turbine
Prime MoverSteam Turbine
OwnershipSingle Owner
Nameplate Capacity2.5 MW
Nameplate Power Factor0.8
Summer Capacity2 MW
Winter Capacity2 MW
Minimum Load0.6 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJanuary 1951
Combined Heat & Power Yes
Sector NameCommercial CHP (5)
Topping Or BottomingT
Energy SourceNatural Gas / Distillate Fuel Oil
Startup SourceNatural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsYes
Cofire FuelsYes
Switch Between Oil And Natural GasYes
Multifuel Details
Cofire Energy SourceNG / DFO
Switch When OperatingYes
Net Summer Capacity With Natural Gas2 MW
Net Winter Capacity With Natural Gas2 MW
Net Summer Capacity With Oil2 MW
Net Winter Capacity With Oil2 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Air Permit LimitsYes

Generator GEN2 Details Operating January 1951

TechnologyNatural Gas Steam Turbine
Prime MoverSteam Turbine
OwnershipSingle Owner
Nameplate Capacity2.5 MW
Nameplate Power Factor0.8
Summer Capacity2 MW
Winter Capacity2 MW
Minimum Load0.6 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJanuary 1951
Combined Heat & Power Yes
Sector NameCommercial CHP (5)
Topping Or BottomingT
Energy SourceNatural Gas / Distillate Fuel Oil
Startup SourceNatural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsYes
Cofire FuelsYes
Switch Between Oil And Natural GasYes
Multifuel Details
Cofire Energy SourceNG / DFO
Switch When OperatingYes
Net Summer Capacity With Natural Gas2 MW
Net Winter Capacity With Natural Gas2 MW
Net Summer Capacity With Oil2 MW
Net Winter Capacity With Oil2 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Air Permit LimitsYes

Generator GEN3 Details Operating January 1968

TechnologyNatural Gas Steam Turbine
Prime MoverSteam Turbine
OwnershipSingle Owner
Nameplate Capacity6.3 MW
Nameplate Power Factor0.85
Summer Capacity6.1 MW
Winter Capacity6.1 MW
Minimum Load1 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJanuary 1968
Combined Heat & Power Yes
Sector NameCommercial CHP (5)
Topping Or BottomingT
Energy SourceNatural Gas / Distillate Fuel Oil
Startup SourceNatural Gas
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsYes
Cofire FuelsYes
Switch Between Oil And Natural GasYes
Multifuel Details
Cofire Energy SourceNG / DFO
Switch When OperatingYes
Net Summer Capacity With Natural Gas6.1 MW
Net Winter Capacity With Natural Gas6.1 MW
Net Summer Capacity With Oil6.1 MW
Net Winter Capacity With Oil6.1 MW
Time To Switch From Gas To Oil1H
Time To Switch From Oil To Gas1H
Factors That Limit SwitchingYes
Air Permit LimitsYes

Generator EG1 Details Standby June 2001

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2 MW
Nameplate Power Factor0.8
Summer Capacity2 MW
Winter Capacity2 MW
Minimum Load0.1 MW
Uprate/Derate Completed No
StatusStandby
Synchronized To Transmission GridYes
First Operation DateJune 2001
Combined Heat & Power No
Sector NameCommercial CHP (5)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator EG2 Details Standby June 2001

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2 MW
Nameplate Power Factor0.8
Summer Capacity2 MW
Winter Capacity2 MW
Minimum Load0.1 MW
Uprate/Derate Completed No
StatusStandby
Synchronized To Transmission GridYes
First Operation DateJune 2001
Combined Heat & Power No
Sector NameCommercial CHP (5)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator EG3 Details Standby June 2001

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2 MW
Nameplate Power Factor0.8
Summer Capacity2 MW
Winter Capacity2 MW
Minimum Load0.1 MW
Uprate/Derate Completed No
StatusStandby
Synchronized To Transmission GridYes
First Operation DateJune 2001
Combined Heat & Power No
Sector NameCommercial CHP (5)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator GEN6 Details Operating January 2006

TechnologyAll Other
Prime MoverSteam Turbine
OwnershipSingle Owner
Nameplate Capacity6.5 MW
Nameplate Power Factor0.85
Summer Capacity2.8 MW
Winter Capacity2.8 MW
Minimum Load0.6 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateJanuary 2006
Combined Heat & Power Yes
Sector NameCommercial CHP (5)
Topping Or BottomingT
Energy SourcePurchased Steam
Startup SourcePurchased Steam
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load12H
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator DG4 Details Operating May 2009

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2 MW
Nameplate Power Factor0.8
Summer Capacity2 MW
Winter Capacity2 MW
Minimum Load0.1 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateMay 2009
Combined Heat & Power No
Sector NameCommercial CHP (5)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Switch Between Oil And Natural GasNo

Generator DG5 Details Operating April 2011

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity2 MW
Nameplate Power Factor0.8
Summer Capacity2 MW
Winter Capacity2 MW
Minimum Load0.1 MW
Uprate/Derate Completed No
StatusOperating
First Operation DateApril 2011
Combined Heat & Power No
Sector NameCommercial CHP (5)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Switch Between Oil And Natural GasNo

Generator DG8 Details Standby December 2021

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity3.1 MW
Nameplate Power Factor0.8
Summer Capacity3.1 MW
Winter Capacity3.1 MW
Minimum Load0.6 MW
Uprate/Derate Completed No
StatusStandby
Synchronized To Transmission GridYes
First Operation DateDecember 2021
Combined Heat & Power No
Sector NameCommercial CHP (5)
Energy SourceDistillate Fuel Oil
Solid Fuel Gasification No
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Generator DG10 Details Standby July 2021

TechnologyPetroleum Liquids
Prime MoverInternal Combustion Engine
OwnershipSingle Owner
Nameplate Capacity3.1 MW
Nameplate Power Factor0.8
Summer Capacity3.1 MW
Winter Capacity3.1 MW
Minimum Load0.6 MW
Uprate/Derate Completed No
StatusStandby
Synchronized To Transmission GridYes
First Operation DateJuly 2021
Combined Heat & Power No
Sector NameCommercial CHP (5)
Energy SourceDistillate Fuel Oil
Carbon Capture TechnologyNo
Time From Cold Shutdown To Full Load10M
Multiple FuelsNo
Cofire FuelsNo
Switch Between Oil And Natural GasNo

Franklin Heating Station Plant Owners

Owner NameAddressGeneratorOwnership
We couldn't locate any owners for this plant

Power Plants with Similar Net Generation

Power plants with a similar annual net generation from Natural Gas.

RankPlant NamePlant LocationAnnual Generation
#1085DeCordova Steam Electric StationGranbury, TX36.9 GWh
#1086Wayne County Energy ComplexGoldsboro, NC58.3 GWh
#1087Ralph GreenPleasant Hill, MO49.9 GWh
#1088Georgia-Pacific Cedar SpringsCedar Springs, GA533.5 GWh
#1089CopperEl Paso, TX49.8 GWh
#1090Indeck Oswego Energy CenterOswego, NY49.8 GWh
#1091Hoffmann LaRocheNutley, NJ50.0 GWh
#1092MMSD Jones Island WastewaterMilwaukee, WI58.7 GWh
#1093South Energy CenterGainesville, FL49.3 GWh
#1094Amalgamated Sugar LLC NampaNampa, ID49.3 GWh
#1096International Paper Red River MillCampti, LA370.6 GWh
#1097Blount StreetMadison, WI48.8 GWh
#1098General ChemicalGreen River, WY199.7 GWh
#1099GraysonGlendale, CA48.4 GWh
#1100Indiana Harbor E 5 AC StationEast Chicago, IN655.1 GWh
#1101San Diego State UniversitySan Diego, CA49.1 GWh
#1102International Paper Franklin MillFranklin, VA257.8 GWh
#1103Bridgeport Gas Processing PlantBridgeport, TX47.9 GWh
#1104Argonne National Laboratory CHPLemont, IL47.9 GWh
#1105Kalkaska CT #1Kalkaska, MI47.8 GWh

Nearby Power Plants

Below are closest 20 power plants surrounding Franklin Heating Station.

Plant NamePlant LocationAnnual GenerationDistance
4710 HostingRochester, MN29.0 MWh4.5 mi
Bear Grove SolarByron, MN1.8 GWh9.6 mi
Cascade CreekRochester, MN29.0 GWh1.5 mi
Crux Community SolarKasson, MN1.8 GWh11.4 mi
Dodge Holdco Solar CSGKasson, MN6.5 GWh14.5 mi
DodgeSun CSGKasson, MN9.5 GWh11.2 mi
Hwy 14 Holdco Solar CSGByron, MN7.9 GWh6.3 mi
IBM WestRochester, MN25.0 MWh3.5 mi
Lange SolarByron, MN1.9 GWh8.6 mi
Maston Garden SolarKasson, MN1.7 GWh11.3 mi
Novel Bartel Solar CSGByron, MN1.8 GWh10.6 mi
Novel Byron Solar CSGByron, MN1.9 GWh7.7 mi
Novel DeCook Solar CSGByron, MN1.5 GWh8 mi
Olmsted Waste EnergyRochester, MN46.7 GWh1.7 mi
Rochester HydroMazeppa, MN10.5 GWh13.3 mi
Saint Marys Hospital Power PlantRochester, MN55.5 GWh5.4 mi
Tweite Community Solar LLCByron, MN1.7 GWh10.4 mi
Water Reclamation PlantRochester, MN3.9 GWh3.1 mi
Westside Energy StationRochester, MN37.1 GWh4.5 mi
Westside SolarRochester, MN17.0 GWh4.7 mi